An Apparatus to Control and Monitor the Para-D2 Concentration in a Solid Deuterium, Superthermal Source of Ultra-cold Neutrons
C.-Y. Liu, S. K. Lamoreaux, A. Saunders, D. Smith, A. R. Young
Abstract
Controlling and measuring the concentration of para-D2 is an essential step toward realizing solid deuterium as an intense ultra-cold neutron (UCN) source. To this end, we implemented an experimental technique to convert para- to ortho-deuterium molecules by flowing D2 gas through a cryogenic cell filled with paramagnetic hydrous ferric oxide granules. This process efficiently reduced the para-D2 concentration from 33.3% to 1.5%. Rotational Raman spectroscopy was applied to measure the residual para-D2 contamination to better than 2 parts in 10^3, and the hydrogen contamination to 1 part in 10^3. We also contrast our optical technique to conventional thermal conductivity measurements of the para-D2 concentration, reporting some of the relevant strengths and weaknesses of our implementation of each technique.