Alzheimer s & Dementia : Diagnosis, Assessment & Disease Monitoring | 2021
P‐tau/Aβ42 and Aβ42/40 ratios in CSF are equally predictive of amyloid PET status
Abstract
Abstract Introduction Measurement of amyloid beta (Aβ40 and Aβ42) and tau (phosphorylated tau [p‐tau] and total tau [t‐tau]) in cerebrospinal fluid (CSF) can be utilized to differentiate clinical and preclinical Alzheimer s disease dementia (AD) from other neurodegenerative processes. Methods CSF biomarkers were measured in 150 participants from the Mayo Clinic Study of Aging and the Alzheimer s Disease Research Center. P‐tau/Aβ42 (Roche Elecsys, Fujirebio LUMIPULSE) and Aβ42/40 (Fujirebio LUMIPULSE) ratios were compared to one another and to amyloid positron emission tomography (PET) classification. Results Strong correlation was observed between LUMIPULSE p‐tau/Aβ42 and Aβ42/40, as well as Elecsys and LUMIPULSE p‐tau/Aβ42 and Aβ42/40 (Spearman s ρ = –0.827, –0.858, and 0.960, respectively). Concordance between LUMIPULSE p‐tau/Aβ42 and Aβ42/40 was 96% and between Elecsys p‐tau/Aβ42 and both LUMIPULSE ratios was 97%. All ratios had > 94% overall, positive, and negative percent agreement with amyloid PET classification. Discussion These data suggest that p‐tau/Aβ42 and Aβ42/40 ratios provide similar clinical information in the assessment of amyloid pathology.