Journal of Orthopaedic Research | 2019

Synchrotron MicroCT Reveals the Potential of the Dual Contrast Technique for Quantitative Assessment of Human Articular Cartilage Composition

 
 
 
 
 
 
 
 
 
 

Abstract


Dual contrast micro computed tomography (CT) shows potential for detecting articular cartilage degeneration. However, the performance of conventional CT systems is limited by beam hardening, low image resolution (full‐body CT), and long acquisition times (conventional microCT). Therefore, to reveal the full potential of the dual contrast technique for imaging cartilage composition we employ the technique using synchrotron microCT. We hypothesize that the above‐mentioned limitations are overcome with synchrotron microCT utilizing monochromatic X‐ray beam and fast image acquisition. Human osteochondral samples (n\u2009=\u200941, four cadavers) were immersed in a contrast agent solution containing two agents (cationic CA4+ and non‐ionic gadoteridol) and imaged with synchrotron microCT at an early diffusion time point (2\u2009h) and at diffusion equilibrium (72\u2009h) using two monochromatic X‐ray energies (32 and 34\u2009keV). The dual contrast technique enabled simultaneous determination of CA4+ (i.e., proteoglycan content) and gadoteridol (i.e., water content) partitions within cartilage. Cartilage proteoglycan content and biomechanical properties correlated significantly (0.327\u2009<\u2009r\u2009<\u20090.736, p\u2009<\u20090.05) with CA4+ partition in superficial and middle zones at both diffusion time points. Normalization of the CA4+ partition with gadoteridol partition within the cartilage significantly (p\u2009<\u20090.05) improved the detection sensitivity for human osteoarthritic cartilage proteoglycan content, biomechanical properties, and overall condition (Mankin, Osteoarthritis Research Society International, and International Cartilage Repair Society grading systems). The dual energy technique combined with the dual contrast agent enables assessment of human articular cartilage proteoglycan content and biomechanical properties based on CA4+ partition determined using synchrotron microCT. Additionally, the dual contrast technique is not limited by the beam hardening artifact of conventional CT systems. © 2019 The Authors. Journal of Orthopaedic Research® published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 38:563–573, 2020

Volume 38
Pages 563 - 573
DOI 10.1002/jor.24479
Language English
Journal Journal of Orthopaedic Research

Full Text