Medical Physics | 2019

Artifact correction in low‐dose dental CT imaging using Wasserstein generative adversarial networks

 
 
 
 
 
 
 
 
 

Abstract


PURPOSE\nIn recent years, health risks concerning high-dose x-ray radiation have become a major concern in dental computed tomography (CT) examinations. Therefore, adopting low-dose computed tomography (LDCT) technology has become a major focus in the CT imaging field. One of these LDCT technologies is downsampling data acquisition during low-dose x-ray imaging processes. However, reducing the radiation dose can adversely affect CT image quality by introducing noise and artifacts in the resultant image that can compromise diagnostic information. In this paper, we propose an artifact correction method for downsampling CT reconstruction based on deep learning.\n\n\nMETHOD\nWe used clinical dental CT data with low-dose artifacts reconstructed by conventional filtered back projection (FBP) as inputs to a deep neural network and corresponding high-quality labeled normal-dose CT data during training. We trained a generative adversarial network (GAN) with Wasserstein distance (WGAN) and mean squared error (MSE) loss, called m-WGAN, to remove artifacts and obtain high-quality CT dental images in a clinical dental CT examination environment.\n\n\nRESULTS\nThe experimental results confirmed that the proposed algorithm effectively removes low-dose artifacts from dental CT scans. In addition, we showed that the proposed method is efficient for removing noise from low-dose CT scan images compared to existing approaches. We compared the performances of the general GAN, convolutional neural networks, and m-WGAN. Through quantitative and qualitative analysis of the results, we concluded that the proposed m-WGAN method resulted in better artifact correction performance preserving the texture in dental CT scanning.\n\n\nCONCLUSIONS\nThe image quality evaluation metrics indicated that the proposed method effectively improves image quality when used as a postprocessing technique for dental CT images. To the best of our knowledge, this work is the first deep learning architecture used with a commercial cone-beam dental CT scanner. The artifact correction performance was rigorously evaluated and demonstrated to be effective. Therefore, we believe that the proposed algorithm represents a new direction in the research area of low-dose dental CT artifact correction.

Volume 46
Pages 1686–1696
DOI 10.1002/mp.13415
Language English
Journal Medical Physics

Full Text