European Journal of Nuclear Medicine and Molecular Imaging | 2021

Can the BMI-based dose regimen be used to reduce injection activity and to obtain a constant image quality in oncological patients by 18F-FDG total-body PET/CT imaging?

 
 
 
 
 
 
 
 
 
 
 
 

Abstract


PET image quality is influenced by the patient size according to the current guideline. The study aimed to propose an optimized dose regimen to yield a constant image quality independent of patient habitus to meet the clinical needs. A first patient cohort of 78 consecutive oncological patients (59.7\u2009±\u200913.7 years) who underwent a total-body PET/CT scan were retrospectively enrolled to develop the regimen. The patients were randomly distributed in four body mass index (BMI) groups according to the World Health Organization (WHO) criteria. The liver SNR (signal-to-noise ratio, SNRL) was obtained by manually drawing regions of interest (ROIs) and normalized (SNRnorm) by the product of injected activity and acquisition time. Fits of SNRnorm against different patient-dependent parameters were performed to determine the best correlating parameter and fit method. A qualitative assessment on image quality was performed using a 5-point Likert scale to determine the acceptable threshold of SNRL. Thus, an optimized regimen was proposed and validated by a second patient cohort consisted of prospectively enrolled 38 oncological patients. The linear fit showed SNRnorm had the strongest correlation (R2\u2009=\u20090.69) with the BMI than other patient-dependent parameters and fit method. The qualitative assessment indicated a SNRL value of 14.0 as an acceptable threshold to achieve sufficient image quality. The optimized dose regimen was determined as a quadratic relation with BMI: injected activity (MBq)\u2009=\u200939.2 (MBq)/(−\u20090.03*BMI\u2009+\u20091.49)2. In the validation study, the SNRL no longer decreased with the increase of BMI. There was no significant difference of the image quality regarding the value of SNRL between different BMI groups (p\u2009>\u20090.05). In addition, the injected activity was reduced by 75.6\u2009±\u20092.9%, 72.1\u2009±\u20094.0%, 67.1\u2009±\u20094.4%, and 64.8\u2009±\u20093.5% compared with the first cohort for the four BMI groups, respectively. The study proposed a quadratic relation between the 18F-FDG injected activity and the patient’s BMI for total-body 18F-FDG PET imaging. In this regimen, the image quality can maintain in a constant level independent of patient habitus and meet the clinical requirement with a reduced injected activity.

Volume None
Pages 1 - 10
DOI 10.1007/s00259-021-05462-5
Language English
Journal European Journal of Nuclear Medicine and Molecular Imaging

Full Text