Annals of Nuclear Medicine | 2021

First clinical assessment of [18F]MC225, a novel fluorine-18 labelled PET tracer for measuring functional P-glycoprotein at the blood–brain barrier

 
 
 
 
 
 
 
 
 
 
 

Abstract


5-(1-(2-[18F]fluoroethoxy))-[3-(6,7-dimethoxy-3,4-dihydro-1H-isoquinolin-2-yl)-propyl]-5,6,7,8-tetrahydronaphthalen ([18F]MC225) is a selective substrate for P-glycoprotein (P-gp), possessing suitable properties for measuring overexpression of P-gp in the brain. This is the first-in-human study to examine safety, radiation dosimetry and P-gp function at the blood–brain barrier (BBB) of [18F]MC225 in healthy subjects. [18F]MC225 biodistribution and dosimetry were determined in 3 healthy male subjects, using serial 2 h and intermittent 4 and 6 h whole-body PET scans acquired after [18F]MC225 injection. Dynamic [18F]MC225 brain PET (90 min) was obtained in 5 healthy male subjects. Arterial blood was sampled at various time intervals during scanning and the fraction of unchanged [18F]MC225 in plasma was determined. T1-weighted MRI was performed for anatomical coregistration. Total distribution volume (VT) was estimated using 1- and 2-tissue-compartment models (1-TCM and 2-TCM, respectively). VT was also estimated using the Logan graphical method (Logan plot) (t*\u2009=\u200920 min). Surrogate parameters without blood sampling (area-under the curve [AUC] of regional time–activity curves [TACs] and negative slope of calculated TACs) were compared with the VT values. No serious adverse events occurred throughout the study period. Although biodistribution implied hepatobiliary excretion, secretion of radioactivity from liver to small intestine through the gallbladder was very slow. Total renal excreted radioactivity recovered during 6 h after injection was\u2009<\u20092%ID. Absorbed dose was the highest in the pancreas (mean\u2009±\u2009SD, 203\u2009±\u200945 μGy/MBq) followed by the liver (83\u2009±\u200911 μGy/MBq). Mean effective dose with and without urination was 17\u2009±\u20091 μSv/MBq. [18F]MC225 readily entered the brain, distributing homogeneously in grey matter regions. 2-TCM provided lower Akaike information criterion scores than did 1-TCM. VT estimated by Logan plot was well correlated with that of 2-TCM (r2\u2009>\u20090.9). AUCs of TACs were positively correlated with VT (2-TCM) values (r2: AUC0-60 min\u2009=\u20090.61, AUC0-30 min\u2009=\u20090.62, AUC30-60 min\u2009=\u20090.59, p\u2009<\u20090.0001). Negative slope of SUV TACs was negatively correlated with VT (2-TCM) values (r2\u2009=\u20090.53, p\u2009<\u20090.0001). This initial evaluation indicated that [18F]MC225 is a suitable and safe PET tracer for measuring P-gp function at the BBB.

Volume 35
Pages 1240 - 1252
DOI 10.1007/s12149-021-01666-9
Language English
Journal Annals of Nuclear Medicine

Full Text