Drug Safety | 2021

Comment on: Frequency and Associated Costs of Anaphylaxis- and Hypersensitivity-Related Adverse Events for Intravenous Iron Products in the USA: An Analysis Using the US Food and Drug Administration Adverse Event Reporting System

 

Abstract


Having read the article by Trumbo et al. [1], published in Drug Safety, I wish to express several serious concerns. While this article was interesting, the authors used a methodology specifically proscribed by the US FDA. This methodology is also referenced in Wysowski et al. [2], the authors of which are all from the FDA and concluded not only that “allergic reactions are possible with all four parenteral iron products” but also that the current system of spontaneous adverse event reporting, particularly in the absence of headto-head trials, does not allow the relative rates of serious adverse events (SAEs) to be determined. Given this strong conclusion, it is prudent to look at the available head-to-head trials and comment on one of the studies cited by Trumbo et al. [1], that of Wang et al. [3] published in JAMA. The FIRM trial by Adkinson et al. [4], also referenced in Trumbo et al. [1], used a double-blind prospective paradigm and examined 1997 patients who received two doses of either ferumoxytol or ferric carboxymaltose (FCM) according to the FDA label. No differences in SAEs were found. Trumbo et al. [1], funded by the manufacturer of FCM, failed to mention prospective comparisons of FCM and iron sucrose, ferumoxytol and iron sucrose, ferric derisomaltose (formerly iron isomaltoside) and iron sucrose, or ferric derisomaltose and FCM [5–8]. None of these studies reported any differences in adverse events. Nor did they mention the study by Wolf et al. [8], published in JAMA, which reported a much higher incidence of significant hypophosphatemia with FCM than with derisomaltose. The authors also omitted a recently published meta-analysis of the prospective randomized trials, which reported no difference in adverse events among the “dextran-derived” formulations and FCM and iron sucrose, effectively mitigating benefit from the inappropriate use of the term “dextran derived.” In Tables e3 and e4 in the online supplementary material for Wang et al. [3], iron dextran had the lowest risk of death within 24 h of administration of any iron formulation, effectively contradicting their own conclusions [10]. Further, during the study, the only truly dangerous iron formulation, high-molecular-weight (HMW) iron dextran, was still available, and the authors did not distinguish between this now unavailable HMW formulation and the much safer lowmolecular-weight formulation. Given these data, the Wang et al. [3] paper should not be used to support the relative safety of any product over another. I have previously reviewed, under the Freedom of Information Act, thousands of spontaneous AE reports submitted to the FDA over a 10-year period [11]. It was impossible to glean which patients received inappropriate premedication with diphenhydramine or even more inappropriate interventions with vasopressors or antihistamines, all of which convert self-limited minor infusion reactions to hemodynamically significant SAEs, which are then ostensibly attributed to the intravenous iron. Considering the burgeoning use of intravenous iron in a litany of maladies in which oral iron is either ineffective or harmful, I believe the conclusions in Trumbo et al. [1] are inaccurate, inconsistent with the overwhelming preponderance of prospective randomized published evidence, misrepresentative, and harmful to the field. Of concern is that This comment refers to the article available online at https ://doi. org/10.1007/s4026 4-020-01022 -2.

Volume 44
Pages 609 - 610
DOI 10.1007/s40264-021-01058-y
Language English
Journal Drug Safety

Full Text