American Journal of Infection Control | 2021

SARS-CoV-2 Detection in Air Samples from Inside Heating, Ventilation, and Air Conditioning (HVAC) Systems- COVID Surveillance in Student Dorms

 
 
 
 
 

Abstract


\n Background\n The COVID-19 pandemic affected universities and institutions and caused campus shutdowns with a transition to online teaching models. To detect infections that might spread on campus, we pursued research towards detecting SARS-CoV-2 in air samples inside student dorms.\n \n Methods\n We sampled air in two large dormitories for 3.5 months and a separate isolation suite containing a student who had tested positive for COVID-19. We developed novel techniques employing four methods to collect air samples: Filter Cassettes, Button Sampler, BioSampler, and AerosolSense sampler combined with direct qRT-PCR SARS-CoV-2 analysis.\n \n Results\n For the two large dorms with the normal student population, we detected SARS-CoV-2 in 11 samples. When compared with student nasal swab qRT-PCR testing, we detected SARS-CoV-2 in air samples when a PCR positive COVID-19 student was living on the same floor of the sampling location with a detection rate of 75%. For the isolation dorm, we had a 100% SARS-CoV-2 detection rate with Aerosol Sense sampler.\n \n Conclusion\n Our data suggest air sampling may be an important SARS-CoV-2 surveillance technique, especially for buildings with congregant living settings (dorms, correctional facilities, barracks). Future building designs and public health policies should consider implementation of HVAC surveillance.\n

Volume None
Pages None
DOI 10.1016/j.ajic.2021.10.009
Language English
Journal American Journal of Infection Control