Device detected arrhythmias - Staying afloat in the data deluge

 
 

Abstract


Pacemakers have long ceased to be devices that only provide pacing support for bradycardia. The advanced devices of today not only provide various optimizations of pacing parameters, but also record high rates in either chamber, providing data that may sometimes be valuable, but often leave the treating physician at a loss on how to deal with this information. The significance of atrial high rates (AHR) recorded in pacemakers has been studied for some time now. Based on the evidence from multiple studies it appears that device detected AHR could be associated with a thromboembolic risk, when it lasts beyond a specified duration, and especially in the presence of other risk factors. This provides an opportunity to treat these high risk patients with anticoagulation and potentially prevent strokes. Our understanding of what to do with ventricular high rate (VHR) events, on the other hand, is less complete at present. Extrapolating from the existing evidence on non sustained VT (NSVT), the significance of device detected VHR may be separately considered in three different groups based on their left ventricular (LV) function. In patients with severe LV dysfunction, the additional prognostic value of non sustained VT appears to be small. In the ESVEM trial [1], LV ejection fraction was the most important determinant of outcomes and NSVT was not predictive of outcomes in multivariate analysis. In the current era where a high proportion of these patients are treated with beta blockers, any prognostic utility of NSVT may be even more blunted [2]. However, these patients are eligible for implantable cardioverter defibrillators because of the low LVEF alone and therefore the presence or absence of NSVT does not guide us in management. In patients with normal LV function, identification of asymptomatic non sustained VT has been considered to carry no prognostic significance [3]. Although patients with a pacemaker have some form of conduction disease requiring pacing, they usually do not have significant LV dysfunction. Therefore we would expect that NSVT is associated with a benign prognosis in them. Previous studies have also shown that the identification of VHR is not associated with increased mortality [4]. In this issue, Isath et al. found that in 502 patients with pacemakers, device detected VHR was not associated with adverse outcomes during follow up [5]. The number of VHR episodes or the ventricular rate during the VHR were likewise also not associated with mortality. They took care to include only those episodes that could be identified as true non sustained VT. This reinforces the conclusion that these VHR episodes add no prognostic information in these patients. The one setting where VHR might be important in predicting

Volume 19
Pages 90 - 91
DOI 10.1016/j.ipej.2019.04.004
Language English
Journal Indian Pacing and Electrophysiology Journal

Full Text