Microscopy and Microanalysis | 2021

Semi-Automated Cryo-EM Sample Loader for TEM SPA Democratization

 
 
 
 
 
 
 
 
 

Abstract


Broader adoption of the cryo electron microscopy (cryo-EM) Single particle analysis (SPA) workflow requires a reliable, easy to use and affordable TEM microscope that can be used for cryo-EM sample assessment and 3D structure determination [1, 2]. Thermo Fisher Scientific therefore introduced a new TEM microscope dedicated to cryo-EM SPA at the end of last year the Thermo ScientificTM Tundra. A new cryo-EM sample loading system was developed to ensure microscope reliability, ease of use, and affordability without the risks of sample deterioration or vacuum failure of the microscope during transfer (a challenge with traditional side entry loading systems). The new semi-automated system for loading cryo-EM samples (SAL) consists of three main modules as depicted in Figure 1. Semi-automation means that many steps of sample transfer are automated and the only remaining manual action consists in moving the Transfer Device (TD) between a Cryo-loading Workstation (CLW) and the TEM microscope. Users can insert one or two grid boxes with cryo-EM grids into the CLW and put up to 5 selected AutoGrids into special slots for automated picking by the TD. Once the AutoGrids are in the slots, the area is sealed to prevent ice buildup and contamination. All next steps are done in a graphical user interface (GUI) via the built-in touch screen. The GUI indicates readiness of the system for loading an AutoGrid to the TEM. Once confirmed by the user, the TD (vented and flushed with dry nitrogen), is loaded with the selected AutoGrid. Next, TD is pumped to a medium vacuum level. The user is then prompted by the system to transfer the TD to from the CLW to the microscope. The microscope recognizes the inserted TD and automatically starts the loading procedure, which consists of pumping down the airlock and handing over the AutoGrids from the TD gripper to the cryo-stage holder inside the TEM. The TD must then be returned to the CLW to finish the routine. For unloading of the inserted AutoGrid, the TD must be cooled down on the CLW, then transferred mounted onto the TEM again. User initiates removal of the inserted AutoGrid via the touch screen and is guided through the process. Several exchanges of cryo-EM samples can be done before the CLW must be heated and recooled to ensure a contamination free environment for handling the cryo-EM samples.

Volume 27
Pages 1342 - 1343
DOI 10.1017/s1431927621005006
Language English
Journal Microscopy and Microanalysis

Full Text