Journal of cardiothoracic and vascular anesthesia | 2021

The Standard Point-of-Care Hemochron Jr. ACT+ Test in Monitoring Heparin Administration for Cardiopulmonary Bypass in Severe Factor XII Deficiency.

 
 
 
 
 

Abstract


Coagulation factor XII (FXII) is a plasma serine protease that belongs to the contact activation complex responsible for initiating the intrinsic coagulation pathway. FXII deficiency is a rare congenital disorder that is not associated with an increased tendency for bleeding. However, as contact activation is impaired in FXII deficiency, both the celite- and kaolin-initiated activated clotting time (ACT) measurements are prolonged markedly, which poses a challenge for anticoagulation monitoring in patients undergoing cardiac surgery. The authors successfully have used the standard Hemochron Jr. ACT+ test, which is activated by silica and phospholipid in addition to kaolin, to monitor anticoagulation for cardiopulmonary bypass in two patients with severe FXII deficiency. The ACT+ test showed low baseline values, increased adequately in response to heparin, and decreased to baseline after protamine. Importantly, there was no abnormal intra- or postoperative bleeding nor any thrombotic complications. Furthermore, in vitro dose-response ACT+ testing of FXII-deficient blood with increasing heparin concentrations supports the use of ACT+ in FXII deficiency.

Volume None
Pages None
DOI 10.1053/j.jvca.2021.05.021
Language English
Journal Journal of cardiothoracic and vascular anesthesia

Full Text