Journal of Applied Physics | 2019

Compositional accuracy in atom probe tomography analyses performed on III-N light emitting diodes

 
 
 
 
 
 
 
 
 
 
 
 

Abstract


Laser-assisted atom probe tomography (APT) and high-resolution dark-field electron holography (HR-DFEH) were performed to investigate the composition of a polar [0001] GaN/AlxGa1\u2009−\u2009xN/InyGa1\u2009−\u2009yN light emitting diode. In particular, the III-site fraction of both AlxGa1\u2009−\u2009xN and InyGa1\u2009−\u2009yN alloys was studied adopting a comparative approach. HR-DFEH allows mapping the projected strain with a subnanometer spatial resolution which is used for the calculation of the two-dimensional alloy composition distribution. APT provides three-dimensional alloys composition distribution with a nanometer spatial resolution. However, here we reveal that important inaccuracies affect local composition measurements. A Ga-poor composition is obtained in high DC-electric field regions. Moreover, such inaccuracies may be locally enhanced where the [0001] pole intersects the surface of the analyzed specimen, leading to a lower fraction of Ga measured. III-site fractions closer to the nominal values were measured at low field conditions. Ga loss is thought to be due to preferential DC field induced evaporation of Ga ions between laser pulses. This is explained in terms of formation of a metallic layer on the tip surface during APT analysis, where weak Ga-Ga bonds are formed, promoting the loss of Ga at high field conditions.Laser-assisted atom probe tomography (APT) and high-resolution dark-field electron holography (HR-DFEH) were performed to investigate the composition of a polar [0001] GaN/AlxGa1\u2009−\u2009xN/InyGa1\u2009−\u2009yN light emitting diode. In particular, the III-site fraction of both AlxGa1\u2009−\u2009xN and InyGa1\u2009−\u2009yN alloys was studied adopting a comparative approach. HR-DFEH allows mapping the projected strain with a subnanometer spatial resolution which is used for the calculation of the two-dimensional alloy composition distribution. APT provides three-dimensional alloys composition distribution with a nanometer spatial resolution. However, here we reveal that important inaccuracies affect local composition measurements. A Ga-poor composition is obtained in high DC-electric field regions. Moreover, such inaccuracies may be locally enhanced where the [0001] pole intersects the surface of the analyzed specimen, leading to a lower fraction of Ga measured. III-site fractions closer to the nominal values were measured at low field con...

Volume 126
Pages 124307
DOI 10.1063/1.5113799
Language English
Journal Journal of Applied Physics

Full Text