Journal of Earthquake Engineering | 2019

Controlled Rocking CLT Walls for Buildings in Regions of Moderate Seismicity: Design Procedure and Numerical Collapse Assessment

 
 

Abstract


ABSTRACT Controlled rocking heavy timber walls are designed to rock on their foundations in response to earthquakes. For regions of moderate seismicity, it is proposed that this rocking behaviour can be adequately controlled using only post-tensioning, even with a large force-reduction factor and no supplemental energy dissipation. This article presents a force-based design procedure for controlled rocking cross-laminated timber walls without supplemental energy dissipation, including a method for estimating higher mode effects. Fragility analyses of three prototype walls demonstrate that the procedure can limit the probability of collapse to <10% during a maximum considered earthquake in a region of moderate seismicity.

Volume 23
Pages 750 - 770
DOI 10.1080/13632469.2017.1326421
Language English
Journal Journal of Earthquake Engineering

Full Text