Journal of radiological protection : official journal of the Society for Radiological Protection | 2019

Source term calculation and validation for 18F-production with a cyclotron for medical applications at HZDR.

 
 
 
 
 

Abstract


In this document we present the calculation and experimental validation of a source term for F-18 production with a cyclotron for medical applications operating at 18 MeV proton energy and 30 microA proton current. The Monte Carlo codes MCNP6 and FLUKA were used for the calculation of the source term. In addition, the radiation field around the O-18 enriched water target was simulated with the two codes. To validate the radiation field obtained in the simulation, an experimental program has been started using ctivation samples which are placed close to the water target during an F-18 production run of the cyclotron. After the irradiation, the samples are analyzed and the resulting activation is compared to Monte Carlo calculations of the expected sample activation. We find good agreement between simulations and experimental results, with most calculation to experiment (C/E) ratios well between 0.6 and 1.4.

Volume None
Pages None
DOI 10.1088/1361-6498/AB2AE8
Language English
Journal Journal of radiological protection : official journal of the Society for Radiological Protection