Archive | 2019

High-voltage power supply for x-ray computed tomography and time-delay compensation of cockcroft-walton circuit

 
 

Abstract


In recent years, an image diagnostic apparatus using X-ray is intensively investigated to reduce the radiation exposures amount. Above all, high-speed control of the high voltage generator to control the X-ray output is a very important issue. A Cockcroft-Walton circuit (CW circuit) is one of the method to generate the high voltage output. However, it has problem of the long time delay in the output response due to the huge capacitive component of the CW circuit. Therefore, it is required to achieve the stable output voltage with a quick transient response, which can be obtained by the time delay compensation technique of the CW circuit. This paper proposes an application of a Smith method to compensate for the time delay of the CW circuit output to reduce the undesirable excessive radiation exposure. AS a result of verification through the computer simulation, it has been confirmed that the overshoot of the output voltage can effectively be suppressed and that the optimal response can be realized without sacrificing the high-speed response. The paper indicates some possibilities of further improvement of the CW circuit output response by introducing the more precise compensation technique to the X-ray computed tomography.

Volume 1367
Pages 12052
DOI 10.1088/1742-6596/1367/1/012052
Language English
Journal None

Full Text