Plasma Science and Technology | 2021

Experimental study of core and edge fluctuations by reflectometry on EAST tokamak

 
 
 
 
 
 
 
 
 
 
 
 
 

Abstract


An eight-channel poloidal correlation reflectometer (PCR) with O-mode polarization has been installed in the EAST tokamak to measure the fluctuations from core to edge. The PCR launches eight different frequency microwaves (20.4, 24.8, 33, 40, 42.4, 48, 52.6, 57.2 GHz) into the plasma from the low field side and two poloidally separated antennae are used to receive the reflected waves. As a result, the diagnostic can measure fluctuations in eight (radial)× two (poloidal) spatial positions. The diagnostic has been applied to study the core and edge pedestal fluctuations during an inter-ELM phase in H-mode plasma. This inter-ELM phase can be divided into two stages. In the first stage, a low frequency (<50 kHz) broadband fluctuation dominates in the pedestal gradient region. In the second stage, this fluctuation is strongly suppressed and quasi-coherent fluctuations (QCFs) appear. The QCF’s amplitude increases with the pedestal density gradient, implying density gradient driven instabilities. But the core fluctuations inside the pedestal show no evident changes during the inter-ELM phase.

Volume 23
Pages None
DOI 10.1088/2058-6272/abf4b5
Language English
Journal Plasma Science and Technology

Full Text