Comparison of adaptive and non-adaptive pacing modes on time-to-peak dP/dt in multipoint pacing or standard biventricular pacing with different degrees of intraventricular fusion

 
 
 
 
 

Abstract


\n \n \n Type of funding sources: Public grant(s) – National budget only. Main funding source(s): Norwegian South-East Health Authorities\n \n \n \n We have investigated the timing of the peak left ventricular pressure rise, time to peak dP/dt (Td) as marker of resynchronization to be measured during implantation for detection of effective resynchronization. Td links the time domain (dyssynchrony) to the mechanical domain (pressure) as the dyssynergic muscular contractions resulting from electrical dyssynchrony delays pressure development and hence the timing of peak dP/dt, Td. Td shortens with resynchronization.\n \n \n \n In this study we investigated the acute changes in Td by comparing pacing the left ventricle (LV) with fusion of intrinsic right ventricular (RV) conduction (Adaptive, A) with pacing RV and LV (Non-Adaptive, NA), with and without multipoint pacing (MPP) and with different degrees of intraventricular pacing delays (RV-LV).\n \n \n \n 19 patients with sinus rhythm and LBBB undergoing CRT implantation were studied. We measured pressures with an indwelling LV pressure catheter. Td was calculated as the time from onset of pacing to peak dP/dt, and averaged in 10 subsequent beats at each stage of pacing. We used quadripolar LV pacing leads positioned in what was considered an optimal mid/basal posterolateral/ lateral branch of the coronary sinus and sequential pacing (DDD) was performed; Adaptive and Non-Adaptive pacing was performed at LV distal [LVdist], proximal electrode [LVprox] and at both electrodes as multipoint pacing [MPP]. VV-timing: LV pacing was performed relative to QRS onset (either as a result of intrinsic activation or RV pace, mean\u2009±\u2009SD): 1. LV only -76\u2009±\u200921ms before QRS activation with minimal fusion with RV activation (LVonly); 2. -28\u2009±\u200914ms before QRS activation (Pre); 3. 12\u2009±\u200915ms after (Post) QRS activation. Linear mixed models were used for statistics of the pooled data. Results are estimated marginal means ±SEM, and only significant P\u2009<\u20090.05 changes are reported.\n \n \n \n Average Td (data pooled) with RVP was 173\u2009±\u20092ms, MPP 144\u2009±\u20090.4ms and BIVP 150\u2009±\u20090.4ms. When analyzing the interaction between pacingmode (A,NA), VV-timing (LVonly,Pre,Post) and electrode(LVdist,LVprox,MPP) in all interventions we found that Td was shorter (p\u2009<\u20090.01) with A(Post) for all electrode combinations [LVdist] 143\u2009±\u20094ms, [LVprox] 140\u2009±\u20094ms and [MPP] 134\u2009±\u20094ms, while Td with A(Pre) was shorter with [MPP] 139\u2009±\u20094ms only. A(post)[MPP] provided shorter Td than the other adaptive modes (p\u2009<\u20090.01). NA(Post)[MPP] at 145\u2009±\u20094ms and NA(Post)[LVdist] at 146\u2009±\u20094ms provided the shortest Td (p\u2009<\u20090.01) of the NA pacing modes, and Td with NA(Post)[MPP] was shorter (p\u2009<\u20090.01) than all NA pacing modes.\n \n \n \n Td shortens the most with LV MPP timed to near simultaneous intrinsic RV activation, indicating a beneficial mechanical effect from Adaptive MPP compared to standard biventricular pacing.\n

Volume 23
Pages None
DOI 10.1093/EUROPACE/EUAB116.453
Language English
Journal Europace

Full Text