Current Opinion in Nephrology and Hypertension | 2019

Fluid management and bioimpedance study in peritoneal dialysis

 
 

Abstract


Purpose of review Maintaining euvolaemia is an essential yet challenging objective in management of patients on peritoneal dialysis. Optimal method to assess volume status remains to be determined. In this review, we will discuss the risk factors and clinical outcomes of fluid overload in PD patients, and examine the role of bioimpedance study in fluid management. Recent findings Applying bioimpedance study to measure body composition has attracted increasing attention because it is noninvasive and provides point-of-care assessment of fluid status. Observational studies suggested that presence of residual renal function did not necessarily protect peritoneal dialysis patients from developing fluid overload. This reinforces the importance of fluid restriction in peritoneal dialysis patients, in whom the thirst sensation could be exacerbated by hyperglycaemia. Notably, fluid overload is present in significant portion of asymptomatic patients. Moreover, bioimpedance-defined fluid overload is associated with increase in all-cause mortality, technique failure and possibly excess peritonitis rate. Summary Although future studies should investigate the clinical benefit of bioimpedance-guided fluid management in high-risk subgroup, raising awareness among clinicians, together with structured clinical assessment and dietary counselling are the cornerstone to maintain stable fluid status.

Volume 28
Pages 58–64
DOI 10.1097/MNH.0000000000000466
Language English
Journal Current Opinion in Nephrology and Hypertension

Full Text