Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society | 2019

A New Methodology for Intraoperative Monitoring of the Functional Integrity of the Phrenic Nerve During Cardiothoracic Surgery.

 
 
 
 
 
 
 
 

Abstract


INTRODUCTION\nThe phrenic nerve could be easily injured during cardiothoracic surgeries because of its anatomical relationships. The aim of this study is to describe a new, feasible, and reproducible methodology to achieve a continuous intraoperative neuromonitoring of the phrenic nerve.\n\n\nMETHODS\nConsecutive patients who underwent open-chest surgery were included. The recording active electrode was placed 5 cm superior to the tip of the xiphoid process, and a hook wire inserted at the motor point of the ipsilateral hemidiaphragm was used as the reference electrode.\n\n\nRESULTS\nWe studied 45 patients (92% men, mean age 67 years). Mean height and weight were 167 ± 6.9 cm and 75.6 ± 12.3 kg, respectively. A reproducible compound motor action potential was recorded in 38 (85%) subjects. The mean latency and amplitude values were 9.68 ± 2.40 ms and 1.36 ± 3.83 mV, respectively. No intraoperative events were recorded.\n\n\nCONCLUSIONS\nWe reported a new methodology which allows the assessment of phrenic nerve functional integrity during surgical procedures.

Volume None
Pages None
DOI 10.1097/wnp.0000000000000677
Language English
Journal Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society

Full Text