Field performance of NowCheck Rapid antigen test for SARS-CoV-2 in Kisumu County, western Kenya

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Abstract


Abstract Background Low- and middle-income countries (LMICs) are increasingly adopting low-cost Coronavirus disease 2019 (COVID-19) rapid antigen tests to meet the high demand for SARS-CoV-2 testing. Whilst testing using real-time polymerase chain reaction (RT-PCR) is the current gold standard, its widespread use in LMICs is limited by high costs, turnaround times and is not readily available in most places. COVID-19 antigen tests (Ag-RDT) provide a suitable alternative due to their low cost, rapid turnaround time and easy to set up and use. This study aimed to assess the field performance of the NowCheck COVID-19 antigen kit (Ag-RDT) as a point of care test (POCT) in select healthcare facilities in western Kenya. Methods We conducted a prospective multi-facility field evaluation study of the NowCheck COVID-19 rapid antigen test (Ag-RDT) compared to SARS-CoV-2 RT-PCR (RT-PCR). After obtaining informed consent, trained laboratory technicians collected two pairs of oropharyngeal and nasopharyngeal swabs, both antigen and RT-PCR testing, first for Ag-RDT and next for RT-PCR. We performed Ag-RDTs on-site and shared the results with both the study participants and their healthcare providers within 15-30 minutes. We carried out all RT-PCR tests in a central referral laboratory. The turnaround time for RT-PCR results was typically 24-48 hours. We captured the results of both methods using an electronic digital application. Findings Between December 2020 and March 2021, we enrolled 997 participants who met the Kenyan Ministry of Health COVID-19 case definition. The median age of study participants was 39 years (range one to 80 years), with 54% male. Ag-RDT had a sensitivity of 84.5% (76.0-90.8) and a specificity of 94.4% (95% CI: 92.7-95.8) with an accuracy of 94.2% (92.5- 95.6) when a cycle threshold value (Ct value) of [≤]35 was used. The highest sensitivity of 87.7% (77.2-94.5) was observed in samples with Ct values [≤] 30 and the highest specificity of 97.5% (96.2-98.5) at Ct value of <40. Interpretation The NowCheck COVID-19 Ag-RDT showed good performance in field evaluation in multiple healthcare facilities in a developing country. The sensitivity of the kit exceeded the minimum recommended cut-off of 80% as recommended by WHO1. The high specificity of this kit at 94.4% at Ct values [≤]33 and 97.5% at Ct values <40 matched that of real-time PCR, making it a good rule-out test for symptomatic patients with COVID-19- like symptoms. The faster turnaround time to results, lower cost, simple analytical steps requiring no equipment or infrastructure makes antigen testing an attractive field-screening method to meet the high demand for COVID-19 testing.

Volume None
Pages None
DOI 10.1101/2021.08.12.21261462
Language English
Journal None

Full Text