Int. J. Pervasive Comput. Commun. | 2021

Reliable IoT-based Health-care System for Diabetic Retinopathy Diagnosis to defend the Vision of Patients

 
 
 
 
 

Abstract


\nPurpose\nThe purpose of this paper is to design an Internet-of-Things (IoT) architecture-based Diabetic Retinopathy Detection Scheme (DRDS) proposed for identifying Type-I or Type-II diabetes and to specifically advise the Type-II diabetic patients about the possibility of vision loss.\n\n\nDesign/methodology/approach\nThe proposed DRDS includes the benefits of automatic calculation of clip limit parameters and sub-window for making the detection process completely adaptive. It uses the advantages of extended 5 × 5 Sobels operator for estimating the maximum edges determined through the convolution of 24 pixels with eight templates to achieve 24 outputs corresponding to individual pixels for finding the maximum magnitude. It enhances the probability of connecting pixels in the vascular map with its closely located neighbourhood points in the fundus images. Then, the spatial information and kernel of the neighbourhood pixels are integrated through the Robust Semi-supervised Kernelized Fuzzy Local information C-Means Clustering (RSKFL-CMC) method to attain significant clustering process.\n\n\nFindings\nThe results of the proposed DRDS architecture confirm the predominance in terms of accuracy, specificity and sensitivity. The proposed DRDS technique facilitates superior performance at an average of 99.64% accuracy, 76.84% sensitivity and 99.93% specificity.\n\n\nResearch limitations/implications\nDRDS is proposed as a comfortable, pain-free and harmless diagnosis system using the merits of Dexcom G4 Plantinum sensors for estimating blood glucose level in diabetic patients. It uses the merits of RSKFL-CMC method to estimate the spatial information and kernel of the neighborhood pixels for attaining significant clustering process.\n\n\nPractical implications\nThe IoT architecture comprises of the application layer that inherits the DR application enabled Graphical User Interface (GUI) which is combined for processing of fundus images by using MATLAB applications. This layer aids the patients in storing the capture fundus images in the database for future diagnosis.\n\n\nSocial implications\nThis proposed DRDS method plays a vital role in the detection of DR and categorization based on the intensity of disease into severe, moderate and mild grades. The proposed DRDS is responsible for preventing vision loss of diabetic Type-II patients by accurate and potential detection achieved through the utilization of IoT architecture.\n\n\nOriginality/value\nThe performance of the proposed scheme with the benchmarked approaches of the literature is implemented using MATLAB R2010a. The complete evaluations of the proposed scheme are conducted using HRF, REVIEW, STARE and DRIVE data sets with subjective quantification provided by the experts for the purpose of potential retinal blood vessel segmentation.\n

Volume 17
Pages 220-236
DOI 10.1108/IJPCC-08-2020-0109
Language English
Journal Int. J. Pervasive Comput. Commun.

Full Text