2021 IEEE 4th International Electrical and Energy Conference (CIEEC) | 2021

Research on Automatic Demagnetization for Cylindrical Magnetic Shielding

 
 
 
 
 
 
 
 

Abstract


Magnetic shielding is an important part in atomic clock’s physical system. The demagnetization of the assembled magnetic shielding system plays an important role in improving atomic clock’s performance. In terms of the drawbacks in traditional attenuated alternating-current demagnetizing method, this paper proposes a novel method — automatically attenuated alternating-current demagnetizing method. Which is implemented by controlling the demagnetization current waveform thorough the signal source’s modulation, so that these parameters such as demagnetizing current frequency, amplitude, transformation mode and demagnetizing period are precisely adjustable. At the same time, this demagnetization proceeds automatically, operates easily, and works steadily. We have the pulsed optically pumped (POP) rubidium atomic clock’s magnetic shielding system for the demagnetization experiment, the magnetic field value reached 1nT/7cm. Experiments show that novel method can effectively realize the demagnetization of the magnetic shielding system, and well meets the atomic clock’s working requirements.

Volume None
Pages 1-6
DOI 10.1109/CIEEC50170.2021.9510863
Language English
Journal 2021 IEEE 4th International Electrical and Energy Conference (CIEEC)

Full Text