IEEE Transactions on Industrial Electronics | 2021

Suppression of Lower Order Harmonics for the Full Modulation Range for a Two-Level Inverter-Fed IM Drive With a Switched-Capacitive Filter Technique Forming a 42-Sided Voltage Space Vector Structure

 
 
 
 
 
 

Abstract


This article proposes an inverter topology for the first time for suppression of all lower order harmonics (5th, 7th, 11th, 13th, etc.) up to 39th harmonic. The lower order harmonic suppression is achieved by switching the 42-sided polygonal vectors, which eliminates harmonics in phase voltage without using a passive $LC$ filtering technique. The power circuit topology uses a single dc-link supply for the primary inverter. The secondary inverter is fed with a capacitive supply. A novel topology is proposed for the dense six-level secondary inverter. The lower order harmonics in phase voltage are suppressed using the secondary inverter, which acts like a switched-capacitive filter. This article also proposes a novel capacitor voltage-balancing scheme for the first time, which achieves voltage balancing for secondary inverter capacitors. The voltages of secondary inverter capacitors are balanced using the power balance relationship between the primary inverter and the motor load. An experimental study of the topology and the capacitor-balancing scheme is presented for the validation of proposed scheme.

Volume 68
Pages 6701-6709
DOI 10.1109/TIE.2020.3007079
Language English
Journal IEEE Transactions on Industrial Electronics

Full Text