IEEE Transactions on Power Electronics | 2021

Multiphysical Time- and Frequency-Domain Fault Detection and Isolation Technique for Power-Electronic Converters in DFIG Wind Turbines

 
 
 
 
 

Abstract


A multiphysical time- and frequency-domain fault detection and isolation method for power-electronic converters of wind turbines is presented in this article, with focus on open-circuit faults in doubly-fed induction generator drivetrain topology. In order to reduce the risk of false alarms, the proposed approach combines fault indicators based on a time- and frequency-domain analysis of electrical signals, as well as a frequency-domain analysis of vibration signals. The effectiveness of the method is demonstrated via test bench data recorded under different healthy and faulty operating conditions.

Volume 36
Pages 3793-3802
DOI 10.1109/TPEL.2020.3021306
Language English