Radiology | 2021

Unenhanced Dual-Layer Spectral-Detector CT for Characterizing Indeterminate Adrenal Lesions.

 
 
 
 
 
 
 
 

Abstract


Background Unenhanced dual-layer spectral-detector CT may facilitate adrenal lesion characterization; however, no studies have evaluated its incremental diagnostic yield for indeterminate lesions (unenhanced attenuation >10 HU) in comparison to that with conventional unenhanced CT. Purpose To determine whether spectral attenuation analysis improves characterization of lipid-poor adrenal adenomas from nonadenomas compared to that with mean attenuation and histogram analysis of conventional CT images. Materials and Methods This retrospective study included patients with indeterminate adrenal lesions who underwent unenhanced dual-layer spectral-detector CT between March 2018 and June 2020. Mean attenuation on conventional 120-kVp images (HUconv), histogram-based percentage negative pixels (proportion of all pixels <0 HU) on conventional 120-kVp images, and mean attenuation on virtual monoenergetic images (VMIs) at 40-140 keV were measured for each lesion. The attenuation difference between virtual monoenergetic 140- and 40-keV images (ΔHU; ie, Hounsfield unit at 140 keV - Hounsfield unit at 40 keV) and ΔHU indexed with HUconv (ΔHU index; ie, ΔHU/HUconv × 100) were calculated. Conventional and virtual monoenergetic imaging parameters were compared between lipid-poor adenomas and nonadenomas by using the Mann-Whitney U test. Receiver operating characteristic analysis was performed to determine the sensitivity for attaining at least 95% specificity in characterizing adenomas from nonadenomas; sensitivity was compared by using the McNemar test. Results A total of 232 patients (mean age ± standard deviation, 67 years ± 11; 145 men) with 129 lipid-poor adenomas and 103 nonadenomas were evaluated. HUconv and mean attenuation on VMIs at 40-140 keV were lower and the percentage negative pixels, ΔHU, and ΔHU index higher in lipid-poor adenomas than in nonadenomas (P < .001 for all). Attenuation differences between adenomas and nonadenomas on VMIs were maximal at 40 keV (23 HU at 40 keV vs 5 HU at 140 keV). The highest sensitivities for differentiating adenomas and nonadenomas were achieved for virtual monoenergetic ΔHU index (77% [99 of 129 adenomas]), attenuation on 40-keV images (71% [91 of 129 adenomas]), and ΔHU (67% [87 of 129 adenomas]) compared to HUconv (35% [45 of 129 adenomas]) and percentage negative pixels (30% [39 of 129 adenomas]) (P < .001 for all; specificity, 95% [98 of 103 nonadenomas]). Conclusion Spectral attenuation analysis enabled differentiation of lipid-poor adenomas from nonadenomas with higher sensitivity than mean attenuation or histogram analysis of conventional CT images. © RSNA, 2021 Online supplemental material is available for this article.

Volume None
Pages \n 202435\n
DOI 10.1148/radiol.2021202435
Language English
Journal Radiology

Full Text