BMC Anesthesiology | 2019

The tidal volume challenge improves the reliability of dynamic preload indices during robot-assisted laparoscopic surgery in the Trendelenburg position with lung-protective ventilation

 
 
 
 
 
 
 

Abstract


BackgroundThe reliability of pulse pressure variation (PPV) and stroke volume variation (SVV) is controversial under pneumoperitoneum. In addition, the usefulness of these indices is being called into question with the increasing adoption of lung-protective ventilation using low tidal volume (VT) in surgical patients. A recent study indicated that changes in PPV or SVV obtained by transiently increasing VT (VT challenge) accurately predicted fluid responsiveness even in critically ill patients receiving low VT. We evaluated whether the changes in PPV and SVV induced by a VT challenge predicted fluid responsiveness during pneumoperitoneum.MethodsWe performed an interventional prospective study in patients undergoing robot-assisted laparoscopic surgery in the Trendelenburg position under lung-protective ventilation. PPV, SVV, and the stroke volume index (SVI) were measured at a VT of 6\u2009mL/kg and 3\u2009min after increasing the VT to 8\u2009mL/kg. The VT was reduced to 6\u2009mL/kg, and measurements were performed before and 5\u2009min after volume expansion (infusing 6% hydroxyethyl starch 6\u2009ml/kg over 10\u2009min). Fluid responsiveness was defined as ≥15% increase in the SVI.ResultsTwenty-four of the 38 patients enrolled in the study were responders. In the receiver operating characteristic curve analysis, an increase in PPV\u2009>\u20091% after the VT challenge showed excellent predictive capability for fluid responsiveness, with an area under the curve (AUC) of 0.95 [95% confidence interval (CI), 0.83–0.99, P\xa0<\u20090.0001; sensitivity 92%, specificity 86%]. An increase in SVV\u2009>\u20092% after the VT challenge predicted fluid responsiveness, but showed only fair predictive capability, with an AUC of 0.76 (95% CI, 0.60–0.89, P\xa0<\u20090.0006; sensitivity 46%, specificity 100%). The augmented values of PPV and SVV following VT challenge also showed the improved predictability of fluid responsiveness compared to PPV and SVV values (as measured by VT) of 6\u2009ml/kg.ConclusionsThe change in PPV following the VT challenge has excellent reliability in predicting fluid responsiveness in our surgical population. The change in SVV and augmented values of PPV and SVV following this test are also reliable.Trial registrationThis trial was registered with Clinicaltrials.gov, NCT03467711, 10th March 2018.

Volume 19
Pages None
DOI 10.1186/s12871-019-0807-6
Language English
Journal BMC Anesthesiology

Full Text