BMC Urology | 2021

Metal stent for the ureteral stricture after surgery and/or radiation treatment for malignancy

 
 
 
 
 
 

Abstract


Background To assess the efficacy and safety of self-expanding metal ureteral stent for the stricture following surgery and/or radiation for malignancy. Methods We performed 36 metal ureteral stent insertion procedures (32 patients) between May 2019 and June 2020. The main inclusion criterion was the patients with ureteral stricture due to surgery and/or radiation treatment for malignanc y . The diagnosis of stricture was ascertained by history and radiographic imaging. The etiologies underlying the strictures were: surgery and/or radiation therapy for cervical and rectal cancer, surgery for ovarian cancer. The primary outcome was the stent patency rate, and the secondary outcomes were the postoperative complications and glomerular filtration rate (GFR). Stent patency was defined as stent in situ without evident migration, unanticipated stent exchange or recurrent ureteral obstruction. Cost analysis was calculated from stent cost, anesthesia cost and operating room fee. Results The pre-metallic stent GFR was 22.53\u2009±\u20096.55\xa0mL/min/1.73\xa0m 2 . Eight patients were on double-J stents before insertion of metallic stents. The total annual cost of per patient in our study was $10,600.2 US dollars (range $9394.4–$33,527.4 US dollars). During a median follow-up time of 16\xa0months (range 8–21\xa0months), 27 cases (31 sides, 84%) remained stent patency. Twelve patients died from their primary malignancy carrying a patency stent. Stent migration was observed in 4 patients within 10\xa0months after insertion. Ectopic stents were endoscopically removed and replaced successfully. Three stents were occluded, and no encrustation was seen in our study. Three and four patients had postoperative fever and gross hematuria, respectively. Infection was observed in 2 cases, mandating antibiotics therapy. In addition, postoperative volume of hydronephrosis postoperatively was significantly reduced compared with preoperation (54.18\u2009±\u200915.42 vs 23.92\u2009±\u20098.3, P \u2009=\u20090.019). However, no statistically significant differences regarding GFR, creatinine levels, blood urea nitrogen and hemoglobin existed between preoperation and last follow-up. Conclusions The current study demonstrated that metal ureteral stent is effective and safe in the treatment of stricture following surgery and/or radiation therapy for malignant cancer. Patients hydronephrosis could be improved by the stent placement.

Volume 21
Pages None
DOI 10.1186/s12894-021-00912-6
Language English
Journal BMC Urology

Full Text