BMC Veterinary Research | 2021

Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy

 
 
 
 
 

Abstract


Background Long-term cyclic tensile testing with equine palmar/plantar tendons have not yet been performed due to problems in fixing equine tendons securely and loading them cyclically. It is well established that the biomechanical response of tendons varies during cyclic loading over time. The aim of this study was to develop a clamping device that enables repetitive cyclic tensile testing of equine superficial digital flexor tendon for at least 60 loading cycles and for 5\u2009min. Results A novel cryo-clamp was developed and built. Healthy and collagenase-treated pony SDFTs were mounted in the custom-made cryo-clamp for the proximal tendon end and a special clamping device for the short pastern bone (os coronale). Simultaneously with tensile testing, we used a biplanar high-speed fluoroscopy system (FluoKin) to track tendon movement. The FluoKin system was additionally validated in precision measurements. During the cyclic tensile tests of the SDFTs, the average maximal force measured was 325\u2009N and 953\u2009N for a length variation of 2 and 4\xa0% respectively. The resulting stress averaged 16\u2009MPa and 48\u2009MPa respectively, while the modulus of elasticity was 828\u2009MPa and 1212\u2009MPa respectively. Length variation of the metacarpal region was, on average, 4.87\xa0% higher after incubation with collagenase. The precision of the FluoKin tracking was 0.0377\u2009mm, defined as the standard deviation of pairwise intermarker distances embedded in rigid bodies. The systems accuracy was 0.0287\u2009mm, which is the difference between the machined and mean measured distance. Conclusion In this study, a good performing clamping technique for equine tendons under repetitive cyclic loading conditions is described. The presented cryo-clamps were tested up to 50\u2009min duration and up to the machine maximal capacity of 10 kN. With the possibility of repetitive loading a stabilization of the time-force-curve and changes of hysteresis and creep became obvious after a dozen cycles, which underlines the necessity of repetitive cyclical testing. Furthermore, biplanar high-speed fluoroscopy seems an appropriate and highly precise measurement tool for analysis of tendon behaviour under repetitive load in equine SDFTs.

Volume 17
Pages None
DOI 10.1186/s12917-021-02914-w
Language English
Journal BMC Veterinary Research

Full Text