Annals of Intensive Care | 2021

Predicting fluid responsiveness in non-intubated COVID-19 patients

 

Abstract


© The Author(s) 2021. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creat iveco mmons .org/licen ses/by/4.0/. I read with great interest the article by Caplan et al. [1] about the prediction of fluid responsiveness in spontaneously breathing patients. They nicely showed that when patients perform a standardized respiratory maneuver and the inferior vena cava (IVC) diameter measurements are done precisely 4 cm from the cavo-atrial junction, the magnitude of the IVC respiratory variation becomes highly predictive of fluid responsiveness. The current COVID-19 pandemic is responsible for a surge of patients hospitalized for hypoxemic pneumonia. Most of them are spontaneously breathing and stay on hospital wards where they receive oxygen. In this context of acute respiratory failure (ARF), excessive fluid administration may increase pulmonary leak, worsen arterial hypoxemia and precipitate tracheal intubation. On the other hand, insufficient fluid administration may promote the development of acute kidney injury and hemodynamic instability. Therefore, in severe COVID-19 cases, predicting fluid responsiveness is recommended by international and WHO guidelines. At first sight, the method proposed by Caplan et al. [1] is appealing because it is non-invasive and associated with a high predictive value. However, in practice, it may be difficult to implement for several reasons. First, patients with ARF may have difficulties to cooperate and standardize the way they breath. Second, ARF patients are usually sitting in their bed, with significant respiratory abdomen movements, which does not facilitate the assessment of IVC variations from a sub-costal view—not mentioning the fact that obesity is common in COVID-19 patients. Would Caplan et al. [1] recommend their method in this specific clinical context? Third, because echocardiography is increasingly used by noncardiologists, would Caplan et al. [1] agree with the fact that the level of precision in IVC diameter measurements requested by their method (exactly 4 cm from the cavoatrial junction) may be a challenge for some operators? One should also consider that significant respiratory efforts may induce dramatic changes in intrathoracic pressure and venous return. As a result, in spontaneously breathing patients with ARF, respiratory variations in IVC diameter, or in blood pressure (pulsus paradoxus), or in the pulse oximetry waveform, may depend more on the magnitude of respiratory efforts than on the volume status [2]. I noticed that Caplan et al. [1] excluded patients with active expiration from their evaluation. Do they agree that their method may also have limitations in patients making significant inspiratory efforts? In patients without any clinical and biological signs of shock or acute kidney injury, a fluid restriction strategy is recommended to limit the development of pulmonary edema and prevent ICU admission. In contrast, in patients with hemodynamic instability or biological signs of tissue hypoperfusion, it may be wise to perform a passive leg raising (PLR) maneuver to identify patients who may benefit from receiving fluid (Fig. 1). It is now well established that the lack of increase in blood pressure during a PLR maneuver cannot exclude a significant improvement in blood flow and oxygen delivery. It is therefore recommended to continuously monitor left ventricular stroke volume in order to assess the hemodynamic response to PLR [3]. In patients who have an arterial catheter in place, a pulse contour technique can be proposed to track Open Access

Volume 11
Pages None
DOI 10.1186/s13613-021-00813-9
Language English
Journal Annals of Intensive Care

Full Text