EJNMMI Physics | 2021

Use of population input functions for reduced scan duration whole-body Patlak 18F-FDG PET imaging

 
 
 
 
 
 

Abstract


Abstract Whole-body Patlak images can be obtained from an acquisition of first 6\u2009min of dynamic imaging over the heart to obtain the arterial input function (IF), followed by multiple whole-body sweeps up to 60\u2009min pi. The use of a population-averaged IF (PIF) could exclude the first dynamic scan and minimize whole-body sweeps to 30–60\u2009min pi. Here, the effects of (incorrect) PIFs on the accuracy of the proposed Patlak method were assessed. In addition, the extent of mitigating these biases through rescaling of the PIF to image-derived IF values at 30–60\u2009min pi was evaluated. Methods Using a representative IF and rate constants from the literature, various tumour time-activity curves (TACs) were simulated. Variations included multiplication of the IF with a positive and negative gradual linear bias over 60\u2009min of 5, 10, 15, 20, and 25% (generating TACs using an IF different from the PIF); use of rate constants ( K 1 , k 3 , and both K 1 and k 2 ) multiplied by 2, 1.5, and 0.75; and addition of noise ( μ = 0 and σ = 5, 10 and 15%). Subsequent Patlak analysis using the original IF (representing the PIF) was used to obtain the influx constant ( K i ) for the differently simulated TACs. Next, the PIF was scaled towards the (simulated) IF value using the 30–60-min pi time interval, simulating scaling of the PIF to image-derived values. Influence of variabilities in IF and rate constants, and rescaling the PIF on bias in K i was evaluated. Results Percentage bias in K i observed using simulated modified IFs varied from −\u200916 to 16% depending on the simulated amplitude and direction of the IF modifications. Subsequent scaling of the PIF reduced these K i biases in most cases (287 out of 290) to <\u20095%. Conclusions Simulations suggest that scaling of a (possibly incorrect) PIF to IF values seen in whole-body dynamic imaging from 30 to 60\u2009min pi can provide accurate Ki estimates. Consequently, dynamic Patlak imaging protocols may be performed for 30–60\u2009min pi making whole-body Patlak imaging clinically feasible.

Volume 8
Pages None
DOI 10.1186/s40658-021-00357-8
Language English
Journal EJNMMI Physics

Full Text