Global and Regional Respiratory Mechanics During Robotic-Assisted Laparoscopic Surgery: A Randomized Study.

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Abstract


BACKGROUND\nPneumoperitoneum and nonphysiological positioning required for robotic surgery increase cardiopulmonary risk because of the use of larger airway pressures (Paws) to maintain tidal volume (VT). However, the quantitative partitioning of respiratory mechanics and transpulmonary pressure (PL) during robotic surgery is not well described. We tested the following hypothesis: (1) the components of driving pressure (transpulmonary and chest wall components) increase in a parallel fashion at robotic surgical stages (Trendelenburg and robot docking); and (2) deep, when compared to routine (moderate), neuromuscular blockade modifies those changes in PLs as well as in regional respiratory mechanics.\n\n\nMETHODS\nWe studied 35 American Society of Anesthesiologists (ASA) I-II patients undergoing elective robotic surgery. Airway and esophageal balloon pressures and respiratory flows were measured to calculate respiratory mechanics. Regional lung aeration and ventilation was assessed with electrical impedance tomography and level of neuromuscular blockade with acceleromyography. During robotic surgical stages, 2 crossover randomized groups (conditions) of neuromuscular relaxation were studied: Moderate (1 twitch in the train-of-four stimulation) and Deep (1-2 twitches in the posttetanic count).\n\n\nRESULTS\nPneumoperitoneum was associated with increases in driving pressure, tidal changes in PL, and esophageal pressure (Pes). Steep Trendelenburg position during robot docking was associated with further worsening of the respiratory mechanics. The fraction of driving pressures that partitioned to the lungs decreased from baseline (63% ± 15%) to Trendelenburg position (49% ± 14%, P < .001), due to a larger increase in chest wall elastance (Ecw; 12.7 ± 7.6 cm H2O·L) than in lung elastance (EL; 4.3 ± 5.0 cm H2O·L, P < .001). Consequently, from baseline to Trendelenburg, the component of Paw affecting the chest wall increased by 6.6 ± 3.1 cm H2O, while PLs increased by only 3.4 ± 3.1 cm H2O (P < .001). PL and driving pressures were larger at surgery end than at baseline and were accompanied by dorsal aeration loss. Deep neuromuscular blockade did not change respiratory mechanics, regional aeration and ventilation, and hemodynamics.\n\n\nCONCLUSIONS\nIn robotic surgery with pneumoperitoneum, changes in ventilatory driving pressures during Trendelenburg and robot docking are distributed less to the lungs than to the chest wall as compared to routine mechanical ventilation for supine patients. This effect of robotic surgery derives from substantially larger increases in Ecw than ELs and reduces the risk of excessive PLs. Deep neuromuscular blockade does not meaningfully change global or regional lung mechanics.

Volume None
Pages None
DOI 10.1213/ANE.0000000000004289
Language English
Journal Anesthesia and analgesia

Full Text