Transactions of the ASABE | 2021

A Sample-to-Answer Compact Optical System for On-Site Detection of Candidatus Liberibacter Asiaticus

 
 
 
 
 
 
 
 
 
 
 
 

Abstract


HighlightsA portable system based on real-time fluorescence analysis was developed for field detection of Candidatus Liberibacter asiaticus within 40 min from sample to answer.A smartphone-assisted device was designed for easy operation, reliable nucleic acid amplification, and highly sensitive fluorescence detection, with sensitivity comparable to that of a commercial instrument.A novel homemade 3D printed box was used for in-field reagent storage, and it could maintain low temperature (<4°C) for about 8 hours without power supply.This fully integrated system is stable, easy to use, inexpensive, and has great application prospects in resource-limited areas.Abstract. Candidatus Liberibacter asiaticus (Las) is a main causal agent of huanglongbing (HLB), a destructive disease that has greatly reduced citrus yields and quality. Instruments with high sensitivity and portability are urgently required for on-site testing. In this study, a novel sample-to-answer optical system for on-site detection of Las was developed. Three major functions, including DNA extraction, amplification, and detection, are integrated into a portable case. This system mainly consists of (1) a specially designed 3D printed box for on-site reagent storage that can maintain low temperature (below 4°C) for 7.5 h at ambient temperature (35°C); (2) a custom device, called the IF-Device, for DNA amplification and detection of HLB, with an optimized optical structure, a sensitive signal processing circuit, and a precise temperature control algorithm with an accuracy of ±0.1°C; and (3) a battery-based power supply for the whole system. In a typical test using sodium fluorescein as a standard model, the results showed that the sensitivity of this system (1.0 nM) could easily meet the requirements of fluorescence biosensors. The feasibility of this homemade system was evaluated with samples extracted from infected citrus leaves based on the loop-mediated isothermal amplification (LAMP) method, and the limit of detection (LOD) was approximately 1.0 × 10-4 ng µL-1. The whole detection process for eight samples could be simultaneously accomplished within 40 min, and the results could be displayed on a smartphone in real-time. Moreover, the portable case is anti-interference, low cost, and only 2 kg in weight. Considering its sensitivity, stability, and portability, this highly integrated system possesses promising prospects for in-field detection. Keywords: Field detection, Fluorescence biosensor, Huanglongbing, Isothermal amplification, Sample-to-answer.

Volume 64
Pages 95-102
DOI 10.13031/trans.13937
Language English
Journal Transactions of the ASABE

Full Text