The Journal of Nuclear Medicine | 2019

Improved Scatter Correction to Eliminate Halo Artifacts for 68Ga-Labeled Radiopharmaceuticals in PET Imaging

 
 

Abstract


TOTHE EDITOR: We read with interest the article by Lindemann et al. titled ‘‘Improving 68-Ga-PSMA PET/MR Hybrid Imaging of the Prostate with Un-renormalized Absolute Scatter Correction’’ (1). The authors present a modified PET scatter-correction algorithm to improve halo artifacts sometimes seen around the bladder and kidneys in 68Ga-PSMA PET images. The scatter estimation for these tracers is challenging due to 2 reasons. The first is the extremely high signal-to-background ratio in the bladder and kidneys, which is difficult to capture in traditional scatter-estimation algorithms that assume the spatial distribution of scatter to be low frequency. The second is due to prompt g-ray coincidence events that cannot be distinguished from positron emission coincidence events. Scatter-estimation algorithms are most commonly based on single scatter simulation with either relative or absolute scaling. This study introduces un-renormalized absolute scatter correction, which omits the last scaling step of the standard scatter correction. This modification was found to significantly reduce the halo artifact around the bladder and improves PET/MR hybrid imaging of the prostate. Previously published work cited by the authors includes suppression of the halo artifact through absolute scatter scaling and reduction of the maximum allowed scatter fraction. The authors also cite the potential for double scatter simulation to improve total scatter estimation, which may further improve 68Ga-PSMA PET imaging. However, the paper fails to mention another published method that demonstrated significant reduction of the halo artifacts. Wangerin et al. showed that improvements to the PET scatter algorithm significantly decreased or completely eliminated halo artifacts for 68Ga-PSMA-11 and also for 68Ga-RM2 in the kidneys and bladder regions (2). There were 2 significant modifications to the scatter algorithm that helped to account for the highly targeted uptake and prompt g-emission of these 68Ga-labeled radiopharmaceuticals. The first improved the single scatter estimation through optimization of the subsampling methodology that is used to limit the computation time. The second improved the scatter scaling step by adding an additive offset factor to the model. The conclusions were that image reconstruction with the improved scatter-correction algorithm mitigated washout artifacts and recovered diagnostic image quality in 68Ga-PSMA-11 studies, indicating that the use of diuretics may be avoided. We think that The Journal of Nuclear Medicine readership will benefit from increased awareness of this alternative approach to improved scatter correction when using 68Ga-labeled radiopharmaceuticals.

Volume 60
Pages 1334 - 1334
DOI 10.2967/jnumed.119.230557
Language English
Journal The Journal of Nuclear Medicine

Full Text