Journal of neurosurgery | 2021

MRI-guided stereotactic laser corpus callosotomy for epilepsy: distinct methods and outcomes.

 
 
 
 
 
 
 
 

Abstract


OBJECTIVE\nSeveral small series have described stereotactic MRI-guided laser interstitial thermal therapy for partial callosotomy of astatic and generalized tonic-clonic (GTC) seizures, especially in association with Lennox-Gastaut syndrome. Larger case series and comparison of distinct stereotactic methods for stereotactic laser corpus callosotomy (SLCC), however, are currently lacking. The objective of this study was to report seizure outcomes in a series of adult patients with epilepsy following anterior, posterior, and complete SLCC procedures and to compare the results achieved with a frameless stereotactic surgical robot versus direct MRI guidance frames.\n\n\nMETHODS\nThe authors retrospectively reviewed sequential adult epilepsy surgery patients who underwent SLCC procedures at a single institution. They describe workflows, stereotactic errors, percentage disconnection, hospitalization durations, adverse events, and seizure outcomes after performing anterior, posterior, and complete SLCC procedures using a frameless stereotactic surgical robot versus direct MRI guidance platforms.\n\n\nRESULTS\nThirteen patients underwent 15 SLCC procedures. The median age at surgery was 29 years (range 20-49 years), the median duration of epilepsy was 21 years (range 9-48 years), and median postablation follow-up was 20 months (range 4-44 months). Ten patients underwent anterior SLCC with a median 73% (range 33%-80%) midsagittal length of callosum acutely ablated. Following anterior SLCC, 6 of 10 patients achieved meaningful (> 50%) reduction of target seizures. Four patients underwent posterior (completion) SLCC following prior anterior callosotomy, and 1 patient underwent complete SLCC as a single procedure; 3 of these 5 patients experienced meaningful reduction of target seizures. Overall, 8 of 10 patients in whom astatic seizures were targeted and treated by anterior and/or posterior SLCC experienced meaningful improvement. SLCC procedures with direct MRI guidance (n = 7) versus a frameless surgical robot (n = 8) yielded median radial accuracies of 1.1 mm (range 0.2-2.0 mm) versus 2.4 mm (range 0.6-6.1 mm; p = 0.0011). The most serious adverse event was a clinically significant intraparenchymal hemorrhage in a patient who underwent the robotic technique.\n\n\nCONCLUSIONS\nThis is the largest reported series of SLCC for epilepsy to date. SLCC provides seizure outcomes comparable to open surgery outcomes reported in the literature. Direct MRI guidance is more accurate, which has the potential to reduce the risks of SLCC. Methodological advancements and larger studies are needed.

Volume None
Pages \n 1-13\n
DOI 10.3171/2020.7.JNS20498
Language English
Journal Journal of neurosurgery

Full Text