Periodica Polytechnica Chemical Engineering | 2019

Effect of Volume Loading Rate and C/N on Ship Domestic Sewage Treatment by Two Membrane Bioreactors

 
 
 
 
 
 

Abstract


Design of ship sewage treatment systems that not only satisfy the use of small space on board but also meets International Maritime Organisation (IMO) latest emission standards is still a challenging problem for ship industry. This study provides a comparative disquisition between two different MBR reactors i.e, air-lift multilevel circulation membrane reactor (AMCMBR) and anaerobic/anoxic/ aerobic membrane reactor (AOA-MBR) for domestic sewage treatment. The influence of pollutants volume loading rate (VLR) and C/N on effluent chemical oxygen demand (COD), ammonium nitrogen (NH4 +-N) and TN for marine domestic sewage was analyzed. The results revealed that AMCMBR showed better removal efficiencies for COD and TN than AOA-MBR. The volume of AMCMBR was only half of the AOA-MBR. In addition, high average value of mixed liquor volatile suspended solids (MLVSS)/mixed liquid suspended solids (MLSS) (i.e. 0.75) of AMCMBR indicated high biomass and good pollutants removal achieved by this reactor. An interesting phenomenon was found in the study regarding Urease activity for the two reactors. Urease activity for AMCMBR in different working conditions all exceeded AOA-MBR and there exist no clear difference of NR activities between AMCMBR and AOA-MBR except for low C/N ratio (i.e. 6 and 4). This phenomenon proved that AMCMBR has a greater performance for treating ship domestic wastewater.

Volume 64
Pages 328-339
DOI 10.3311/ppch.14672
Language English
Journal Periodica Polytechnica Chemical Engineering

Full Text