Coatings | 2021

Simulation Study on Centrifugal Spray Evaporation Characteristics and Process Optimization of Desulfurization Wastewater

 
 
 
 

Abstract


As an advanced treatment of desulfurization wastewater, centrifugal spray drying technology, which can achieve a zero liquid discharge target, has attracted wide attention and great interest in recent years. However, the results of previous studies were based on the laboratory-scale centrifugal spray dryer. In order to study the evaporation characteristics of desulfurization wastewater and the parameter optimization of the dryer, the evaporation model of wastewater droplets was established. The effects of parameters such as the angle of the deflectors, gas–liquid ratio and atomizer speed on droplet evaporation were studied by numerical simulation. The results show that with the increase in the angle of the deflectors, the swirl effect of flue gas flow field is more obvious and the time and axial distance required for the complete evaporation of the droplets are shorter. Reducing the gas–liquid ratio will make the average evaporation time longer. Moreover, a higher atomizer speed is helpful for the evaporation of the droplets. The optimum gas–liquid ratio and rotational speed are found to be 9300 m3/Nm3 and 16,000 rpm, respectively.

Volume None
Pages None
DOI 10.3390/COATINGS11070837
Language English
Journal Coatings

Full Text