Electronics | 2021

Accurate Ultrasound Indoor Localization Using Spring-Relaxation Technique

 
 
 
 

Abstract


This paper reports on the development of an ultrasonic sensing-based active localization system. The system employs an ultrasonic array to transmit chirp signals and time-of-flight measurement for ranging. The position of the receiver is estimated iteratively using the spring-relaxation technique. A median and 90-percentile error of 12.4 and 21.7 mm, respectively, were obtained for measurements at 625 positions within a 1.2 m × 1.2 m area testbed. The spring-relaxation technique outperforms the widely adopted linear least square-based lateration technique while using the same ranging data. The performance of the system is benchmarked against that of visible light positioning using the same platform setup. The reported results show the ultrasonic system to be more accurate when compared with the visible light positioning system, which achieved median and 90-percentile errors of 33.7 and 58.6 mm, respectively.

Volume 10
Pages 1290
DOI 10.3390/ELECTRONICS10111290
Language English
Journal Electronics

Full Text