Energies | 2019

An Embedded Sensor Node for the Surveillance of Power Quality

 
 
 
 

Abstract


The energy supply of office buildings and smart homes is a key issue in the global energy system. The growing use of microelectronics-based technology achieves new devices for a more comfortable life and wider use of electronic office equipment. On the one hand, these applications incorporate more and more sensitive electronic devices which are potentially affected by any external electrical transient. On the other hand, the existing electrical loads, which generally use electronic power systems (such as different types of battery chargers, ballasts, inverters, switching power supplies, etc.), generate different kinds of transients in their own electrical internal network. Moreover, improvements in the information of the state of the mains alternating current (AC) power line allows risk evaluation of any disturbance caused to permanently connected electronic equipment, such as computers, appliances, home security systems, phones, TVs, etc. For this reason, it is nowadays more important to introduce monitoring solutions into the electrical network to measure the level of power quality so that it can protect itself when necessary. This article describes a small and compact detector using a low-cost microcontroller and a very simple direct acquiring circuit. In addition; it analyzes different methods to implement various power quality (PQ) surveillance algorithms that can be implemented in this proposed minimum hardware platform. Hence; it is possible to achieve cheap and low-power monitoring devices that can become nodes of a wireless sensor network (WSN). The work shows that using a small computational effort; reasonable execution speed; and acceptable reliability; this solution can be used to detect a variety of large disturbance phenomena and spread the respective failure report through a 433 MHz or 2.4 GHz radio transmitter. Therefore, this work can easily be extended to the Internet of Things (IoT) paradigm. Simultaneously, a software application (PulsAC) has been developed to monitor the microcontroller’s real-time progress and detection capability. Moreover, this high-level code (C++ language), allows us to test and debug the different utilized algorithms that will be later run by the microcontroller unit. These tests have been performed with real signals introduced by a function generator and superimposed on the true AC sine wave

Volume 12
Pages 1561
DOI 10.3390/EN12081561
Language English
Journal Energies

Full Text