Archive | 2021

Investigation on Analysis Method of Environmental Fatigue Correction Factor of Primary Coolant Metal Materials in LWR Water Environment

 
 
 
 
 
 
 

Abstract


The environmental fatigue correction factor (Fen) is mainly used to analyze the influence of the coolant environment on the fatigue life of primary metal materials. Because the calculation of the transformed strain rate is related to the stress history of the component structure, how to determine the strain rate is the most critical step in calculating the Fen. The approaches of the detailed method were given by the Electric Power Research Institute (EPRI) guidelines and RCC-M-2017 Edition Section VI- RPP No. 3 separately, so a gap analysis was performed between the two methods. Furthermore, another average method was also proposed to determine the average strain rate and strain range. Based on the analysis benchmark provided in the EPRI guideline, a simple case study was performed to account for the effect on the fatigue life in applications with different strain rate approaches and different Fen expressions. Finally, two industry case studies were also completed, including on materials of low alloy steel, austenitic stainless steel, and nickel-base alloy. We suggest adopting a more accurate detailed method, and its methodology is recommended to provide more reasonable solutions.

Volume 11
Pages 233
DOI 10.3390/MET11020233
Language English
Journal None

Full Text