Journal of Clinical Medicine | 2021

Rupture Rate, Functional Outcome and Patient Satisfaction after Primary Flexor Tendon Repair with the Modified 4-Strand Core Suture Technique by Tsuge and Using the Arthrex FiberLoop® with Early Motion Rehabilitation

 
 
 

Abstract


Purpose:Our hypothesis was that the rupture rate after primary flexor tendon repair in the modified 4-strand core suture technique using the FiberLoop® (Arthrex, Munich, Germany) is lower than in other suture materials and functional outcome and patient satisfaction are superior compared to the current literature. Patients and methods: A 2-stage retrospective, randomized follow-up study of 143 patients treated with the Arthrex FiberLoop® after flexor tendon injury in zones 2 or 3 from May 2013 to May 2017 was performed. In the 1st stage, the rupture rate of all patients was assessed after a follow-up of at least one year by interview to exclude revision surgery. In the 2nd stage, 20% of the patients could be randomly clinically examined. Functional parameters, such as finger and wrist range of motion measured by goniometer, grip strength measured by Jamar dynamometer (Saehan, South Korea), patient satisfaction measured by school grades (1–6), pain levels measured by visual rating scales (0–10) and functional outcome according to the DASH-score were assessed. The Buck-Gramcko and Strickland scores were calculated. The length of sick leave was recorded. Results: A rupture rate of 2.1% was recorded. 29 patients (20%) were followed up at a mean of 34 ± 7.5 months postoperatively. 10.3% of these patients had an incomplete fingertip palm distance. The mean postoperative grip strength was 24 ± 3.1 kg. 93% of the patients were very satisfied with the treatment. No patient complained of pain postoperatively. The mean postoperative DASH score was 6.7 ± 2.8 points. The mean Buck-Gramcko score was 14 ± 0.2 points. 93% of the patients had excellent and 7% good results according to the Strickland score. 67% of patients had a work accident and returned to work at a mean of 4 ± 0.2 months postoperatively. 31% of patients suffered a non-occupational injury and returned to work at a mean of 3 ± 0.4 months postoperatively. Conclusions: Primary flexor tendon repair in the modified 4-strand core suture technique using the Arthrex FiberLoop® has proven to be a viable treatment option in our series. The rupture rate was lower than in other suture materials. It leads to acceptable pain relief, grip strength and functional outcome. Level of Evidence: IV; therapeutic.

Volume 10
Pages None
DOI 10.3390/jcm10194538
Language English
Journal Journal of Clinical Medicine

Full Text