Molecules | 2019

New Vortex-Synchronized Matrix Solid-Phase Dispersion Method for Simultaneous Determination of Four Anthraquinones in Cassiae Semen

 
 
 
 
 
 

Abstract


In this study, a green ionic-liquid based vortex-synchronized matrix solid-phase dispersion (VS-MSPD) combined with high performance liquid chromatography (HPLC) method was developed as a quantitative determination method for four anthraquinones in Cassiae Semen. Two conventional adsorbents, C18 and silica gel were investigated. The strategy included two steps: Extraction and determination. Wasted crab shells were used as an alternative adsorbent and ionic liquid was used as an alternative solvent in the first step. Factors affecting extraction efficiency were optimized: A sample/adsorbent ratio of 2:1, a grinding time of 3 min, a vortex time of 3 min, and ionic liquid ([Domim]HSO4, 250 mM) was used as eluent in the VS-MSPD procedure. As a result, the established method provided satisfactory linearity (R > 0.999), good accuracy and high reproducibility (RSD < 4.60%), and it exhibited the advantages of smaller sample amounts, shorter extraction time, less volume of elution solvent, and was much more environmental-friendly when compared with other conventional methods.

Volume 24
Pages None
DOI 10.3390/molecules24071312
Language English
Journal Molecules

Full Text