INTER-NOISE and NOISE-CON Congress and Conference Proceedings | 2021

Effect of ceiling and dry-type double floor on heavy-weight floor impact sound in concrete building and CLT building.

 
 
 

Abstract


The air layer between the interior finishes and the structure is used as piping and wiring space. In many cases, ceilings and dry-type double floors are commonly constructed in Japan. However, the effect of the air layer of ceilings and dry-type double floors on the heavy-weight floor\n impact sound insulation performance has not yet quantitatively investigated. Therefore, in this study, the same floor and ceiling structures were constructed for concrete and CLT buildings, and the heavy-weight floor impact sound was investigated. As results, it was confirmed that the reduction\n amount of the heavy-weight floor impact sound by the ceiling tended to be smaller in CLT buildings than in concrete buildings. However, the trends were similar. Due to the dry-type double floor structure, the heavy-weight floor impact sound level was increased in concrete building and decreased\n in CLT building at 63 Hz in the octave band center frequency band. Therefore, it can be said that the dry-type double floor structure can be used to improve the heavy-weight floor impact sound performance in the CLT building.

Volume None
Pages None
DOI 10.3397/in-2021-2298
Language English
Journal INTER-NOISE and NOISE-CON Congress and Conference Proceedings

Full Text