Revista De Chimie | 2021

Experimental Investigation of Two-Phase Flow Patterns in a Vertical to Horizontal Bend Pipe Using Wire-Mesh Sensor

 
 
 
 

Abstract


The air-water two-phase flow plays an important role in many applications of industry fields. Usually, a 90-degree bend is used to connect pipes for changing the direction of flow which influences the two-phase flow pattern. In this paper, the effect of 90-degree bend under different ranges of gas and liquid superficial velocities on the two-phase flow patterns in the horizontal pipe located after the bend was experimentally investigated, and then results were presented and compared in a two-phase flow pattern map. Also, tomographic images and probability density functions were used to capture the cross- section void fraction and its distribution for the two-phase flow patterns. The results revealed that at low liquid and gas flow rates, a stratified-wavy flow pattern was observed as a dominant flow pattern. While the wavy-annular and semiannular flow patterns were observed at a high range of gas flow rates in the horizontal pipe. The results also showed that at the high range of liquid flow rate, bubbly, plug, slug, stratified-wavy, and wavy-annular flow patterns were observed in the horizontal pipe when the gas flow increased. The tomographic images and probability density functions gave good agreement with the experimental observations and results.

Volume 71
Pages 18-33
DOI 10.37358/RC.20.12.8383
Language English
Journal Revista De Chimie

Full Text