Frontiers in bioscience | 2021

Characterization of the differential efficacy of austenitic vs martensitic NiTi rotary files in non-surgical root canal retreatment: a micro-CT analysis.

 
 
 
 
 
 

Abstract


Aim: Our study aims to characterize the differential efficacy of martensitic and austenitic files in root canal retreatment regarding defiling ability, debris management and morphometric features. Materials and methods: A total of 10 human premolar teeth with two separate fully formed roots were selected, prepared with BioRace system (BR) up to a size BR2 (0.04/25). Root canals were filled and then divided according to the file type into two groups (n = 10). Two geometrically identical files have been used with the only difference between them is heat treatment; One Curve (OC) martensitic and One Shape (OS) austenitic. Preoperative and postoperative Micro-CT scans were done for all the samples, and the percent volume of residual filling materials was calculated. Canals reshaping and remaining debris in the canals were assessed by calculating the volume of the canals before and after retreatment using Micro-CT software. Results: The percentages of removed filling materials were similar between both groups (97.2% OC vs 97.8% OS). OS was significantly faster than OC (P < 0.05). Retreatment procedure did not significantly change volume, structure model index, surface area, and canal curvature. OS group transported the canals more than OC at the apical third (P < 0.05). There were no significant differences between both groups concerning un-instrumented surface area and accumulated hard tissue debris (AHTD) (P > 0.05). Conclusion: Under the circumstances of this study, neither file systems could completely remove the filling materials. However, OC resulted in less transportation than OS in the apical one third (P < 0.05). Also, OC resulted less AHTD than OS but with no statistical difference.

Volume 26 9
Pages \n 465-474\n
DOI 10.52586/4959
Language English
Journal Frontiers in bioscience

Full Text