Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where A. Broniatowski is active.

Publication


Featured researches published by A. Broniatowski.


Physics Letters B | 2009

A new high-background-rejection dark matter Ge cryogenic detector

A. Broniatowski; X. Defay; E. Armengaud; L. Bergé; A. Benoit; O. Besida; J. Blümer; A. Chantelauze; M. Chapellier; G. Chardin; F. Charlieux; S. Collin; O. Crauste; M. De Jésus; P. Di Stefano; Y. Dolgorouki; J. Domange; L. Dumoulin; K. Eitel; J. Gascon; G. Gerbier; M. Gros; M. Hannawald; S. Hervé; A. Juillard; H. Kluck; V. Kozlov; R. Lemrani; A. Lubashevskiy; C. Marrache

A new design of a cryogenic germanium detector for dark matter search is presented, taking advantage of the coplanar grid technique of event localisation for improved background discrimination. Experiments performed with prototype devices in the EDELWEISS II setup at the Modane underground facility demonstrate the remarkably high efficiency of these devices for the rejection of low-energy


Physics Letters B | 2010

First results of the EDELWEISS-II WIMP search using Ge cryogenic detectors with interleaved electrodes

E. Armengaud; C. Augier; A. Benoit; L. Bergé; O. Besida; J. Blümer; A. Broniatowski; A. Chantelauze; M. Chapellier; G. Chardin; F. Charlieux; S. Collin; X. Defay; M. De Jésus; P. Di Stefano; Y. Dolgorouki; J. Domange; L. Dumoulin; K. Eitel; J. Gascon; G. Gerbier; M. Gros; M. Hannawald; S. Hervé; A. Juillard; H. Kluck; V. Kozlov; R. Lemrani; P. Loaiza; A. Lubashevskiy

beta


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2003

SICANE: A Detector array for the measurement of nuclear recoil quenching factors using a monoenergetic neutron beam

E. Simon; L. Bergé; A. Broniatowski; R. Bouvier; B. Chambon; M. De Jésus; D. Drain; L. Dumoulin; J. Gascon; J.P. Hadjout; A. Juillard; O. Martineau; C. Pastor; M. Stern; L. Vagneron

, approaching 10


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2004

Calibration of the EDELWEISS cryogenic heat-and-ionization germanium detectors for dark matter search

O. Martineau; A. Benoı̂t; L. Bergé; A. Broniatowski; L. Chabert; B. Chambon; M. Chapellier; G. Chardin; P. Charvin; M. De Jésus; P. Di Stefano; D. Drain; L. Dumoulin; J. Gascon; G. Gerbier; E. Gerlic; C. Goldbach; M. Goyot; M. Gros; J.P. Hadjout; S. Hervé; A. Juillard; A. de Lesquen; M. Loidl; J. Mallet; S. Marnieros; N. Mirabolfathi; L. Mosca; X.-F. Navick; G. Nollez

^5


Physics Letters B | 2005

Sensitivity of the EDELWEISS WIMP search to spin-dependent interactions

A. Benoit; L. Bergé; J. Blümer; A. Broniatowski; B. Censier; L. Chabert; M. Chapellier; G. Chardin; S. Collin; M. De Jésus; H. Deschamps; P. Di Stefano; Y. Dolgorouky; D. Drain; L. Dumoulin; K. Eitel; M. Fesquet; S. Fiorucci; J. Gascon; G. Gerbier; C. Goldbach; M. Gros; R. Gumbsheimer; M. Horn; A. Juillard; A. de Lesquen; M. Luca; J. Mallet; S. Marnieros; L. Mosca

. This opens the road to investigate the range beyond 10


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2007

Measurement of the response of heat-and-ionization germanium detectors to nuclear recoils

A. Benoit; L. Bergé; J. Blümer; A. Broniatowski; B. Censier; A. Chantelauze; M. Chapellier; G. Chardin; S. Collin; X. Defay; M. De Jésus; H. Deschamps; P. Di Stefano; Y. Dolgorouky; L. Dumoulin; K. Eitel; M. Fesquet; S. Fiorucci; J. Gascon; G. Gerbier; C. Goldbach; M. Gros; M. Horn; A. Juillard; R. Lemrani; A. de Lesquen; Marchese Luca; S. Marnieros; L. Mosca; X.-F. Navick

^{-8}


THE THIRTEENTH INTERNATIONAL WORKSHOP ON LOW TEMPERATURE DETECTORS—LTD13 | 2009

Full Inter‐Digitized Detectors For The EDELWEISS‐II Dark Matter Search

S. Marnieros; E. Armengaud; C. Augier; L. Bergé; A. Benoit; O. Besida; J. Blümer; A. Broniatowski; A. Chantelauze; M. Chapellier; G. Chardin; F. Charlieux; S. Collin; O. Crauste; X. Defay; M. De Jésus; P. Di Stefano; Y. Dolgorouki; J. Domange; L. Dumoulin; K. Eitel; J. Gascon; G. Gerbier; M. Gros; M. Hannawald; S. Hervé; A. Juillard; H. Kluck; V. Kozlov; R. Lemrani

pb in the WIMP-nucleon collision cross-sections, as proposed in the EURECA project of a one-ton cryogenic detector mass.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2000

Electronic transport and event localization in germanium low-temperature detectors for the EDELWEISS Dark Matter experiment

A. Broniatowski; N. Mirabolfathi; L. Dumoulin; A. Juillard; L. Bergé

Abstract The EDELWEISS-II Collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months of continuous operation at the Laboratoire Souterrain de Modane have been achieved. The observation of one nuclear recoil candidate above 20 keV in an effective exposure of 144 kgu2009d is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 1.0 × 10 − 7 pb is excluded at 90% CL for a WIMP mass of 80 GeV / c 2 . This result demonstrates for the first time the very high background rejection capabilities of these simple and robust detectors in an actual WIMP search experiment.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2000

Event localization using ballistic phonon signals in sapphire bolometers

G Marie-Magdeleine; A. Broniatowski; N. Mirabolfathi; A. Juillard; L. Bergé; P Perrier; L. Dumoulin

Abstract SICANE is a neutron scattering multidetector facility for the determination of the quenching factor (ratio of the response to nuclear recoils and to electrons) of cryogenic detectors used in direct WIMP searches. Well-collimated monoenergetic neutron beams are obtained with inverse (p,n) reactions. The facility is described, and results obtained for the quenching factors of scintillation in NaI(Tl) and of heat and ionization in Ge are presented.


Journal of Physics: Conference Series | 2006

Status and Outlook of the EDELWEISS Experiment

P. Di Stefano; A. Benoit; L. Bergé; J. Blümer; A. Broniatowski; B. Censier; B. Chambon; A. Chantelauze; M. Chapellier; G. Chardin; M. De Jésus; Y. Dolgorouky; D. Drain; L. Dumoulin; K. Eitel; M. Fesquet; S. Fiorucci; J. Gascon; G. Gerbier; E. Gerlic; C. Goldbach; M. Goyot; M. Gros; M. Horn; S. Hervé; A. Juillard; C. Kikuchi; R. Lemrani; A. de Lesquen; A Lubashevski

Several aspects of the analysis of the data obtained with the cryogenic heat-and-ionization Ge detectors used by the EDELWEISS dark matter search experiment are presented. Their calibration, the determination of their energy threshold, fiducial volume and nuclear recoil acceptance are detailed.

Collaboration


Dive into the A. Broniatowski's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

M. De Jésus

Centre national de la recherche scientifique

View shared research outputs
Top Co-Authors

Avatar

A. Benoit

Centre national de la recherche scientifique

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

J. Blümer

Karlsruhe Institute of Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge