IEEE Transactions on Medical Imaging | 2000

A perspective on needle artifacts in MRI: an electromagnetic model for experimentally separating susceptibility effects

A. Glowinski; G. Adam; Arno Bücker; J. J. Van Vaals; Rolf W. Günther

A thorough understanding of artifacts caused by metallic instruments is essential for the guidance of interventional procedures by magnetic resonance imaging (MRI), because the accurate localization of each instrument is mandatory for this. In the past, this problem has been addressed by several groups, using theoretical, as well as experimental approaches. The artifacts associated with MRI are caused by geometry distortion and intravoxel dephasing. Usually, both effects mingle in the image, and depending on the pulse sequences and its parameters used for data acquisition, these effects are reflected in the image with different magnitude. Here, the authors shortly present the well-known mathematical background of the two underlying effects. Mathematically, both can be treated separately. Here, authors propose a new electromagnetic model which also allows to experimentally separate the effects better than by comparing spin-echo and gradient-echo images of the same object. With this new model, both effects-geometry distortion and intravoxel dephasing-are demonstrated separately using the same gradient-echo pulse sequence for all scans and adjusting the fields of the model properly. Furthermore, as this model allows to adjust both effects independently, it is used to study different weightings of both effects when they appear simultaneously in the image.


Archive | 1996

MRI-system and catheter for interventional procedures

A. Glowinski; Johannes Jacobus Van Vaals


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 1998

Echtzeit-MR mit radialer k-Raumabtastung zur Überwachung angiographischer Interventionen

Arno Bücker; G. Adam; Jörg Neuerburg; A. Glowinski; Claus Nolte-Ernsting; David W. Hunter; S. Großkortenhaus; M. Leenen; Volker Rasche; R. Proksa; J. J. van Vaals; W. Hurtak; Rolf W. Günther


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2000

Aerosoliertes Gadolinium-DTPA zur Darstellung der Lungenventilation in der Magnetresonanztomographie

Patrick Haage; G. Adam; B. Misselwitz; S. Karaagac; Joachim Georg Pfeffer; A. Glowinski; S. Döhmen; Josef Tacke; Rolf W. Günther


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2003

MR-gesteuerte Spiralembolisation von Nierenarterien in einem Tiermodell

Arno Bücker; Jörg Neuerburg; G. Adam; A. Glowinski; J. J. van Vaals; Rolf W. Günther


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2000

[Interventional magnetic resonance imaging--non-invasive imaging for interventions].

Arno Bücker; G. Adam; Jörg Neuerburg; A. Glowinski; Josef Tacke; Rolf W. Günther


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 1997

Kathetervisualisierung in der MR-Tomographie: erste tierexperimentelle Erfahrungen mit Feldinhomogenitätskathetern

G. Adam; A. Glowinski; Jörg Neuerburg; Arno Bücker; J. J. van Vaals; W. Hurtak; Rolf W. Günther


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 1997

MR-gesteuerte Biopsien mit einer hochauflösenden schnellen T2-gewichteten Turbo-Spin-Echo-Sequenz LoLo : Erste klinische Erfahrungen

Arno Bücker; G. Adam; Jörg Neuerburg; A. Glowinski; J. J. van Vaals; Rolf W. Günther


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 1999

Eine stufenlose pneumatische Bewegungsvorrichtung für die dynamische MRT der Halswirbelsäule

Josef Tacke; Joachim Georg Pfeffer; A. Glowinski; K. Birnbaum; Rolf W. Günther


Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 1999

MR-Defäkographie bei 1,5 Tesla mit radialer Echtzeitbildgebung und reduziertem Bildfeld

Josef Tacke; Claus Nolte-Ernsting; A. Glowinski; T. Schäffter; G. Adam; Rolf W. Günther

Collaboration


Dive into the A. Glowinski's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

G. Adam

RWTH Aachen University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Josef Tacke

RWTH Aachen University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge