Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where A.L. Frank is active.

Publication


Featured researches published by A.L. Frank.


Radiation Measurements | 1995

A study of the radiation environment on board the Space Shuttle flight STS-57

G.D. Badhwar; William Atwell; E.V. Benton; A.L. Frank; R.P. Keegan; V.E. Dudkin; O.N. Karpov; Yu.V. Potapov; A.B. Akopova; N.V. Magradze; L.V. Melkumyan; Sh.B. Rshtuni

A joint NASA-Russian study of the radiation environment inside a SPACEHAB 2 locker on Space Shuttle flight STS-57 was conducted. The Shuttle flew in a nearly circular orbit of 28.5 degrees inclination and 462 km altitude. The locker carried a charged particle spectrometer, a tissue equivalent proportional counter (TEPC), and two area passive detectors consisting of combined NASA plastic nuclear track detectors (PNTDs) and thermoluminescent detectors (TLDs), and Russian nuclear emulsions, PNTDs and TLDs. All the detector systems were shielded by the same Shuttle mass distribution. This makes possible a direct comparison of the various dose measurement techniques. In addition, measurements of the neutron energy spectrum were made using the proton recoil technique. The results show good agreement between the integral LET spectrum of the combined galactic and trapped particles using the tissue equivalent proportional counter and track detectors between about 15 keV/micrometers and 200 keV/micrometers. The LET spectrum determined from nuclear emulsions was systematically lower by about 50%, possibly due to emulsion fading. The results show that the TEPC measured an absorbed dose 20% higher than the TLDs, due primarily to an increased TEPC response to neutrons and a low sensitivity of TLDs to high LET particles under normal processing techniques. There is a significant flux of high energy neutrons that is currently not taken into consideration in dose equivalent calculations. The results of the analysis of the spectrometer data will be reported separately.


Radiation Measurements | 2002

Passive dosimetry aboard the Mir Orbital Station: internal measurements

E.R. Benton; E.V. Benton; A.L. Frank

This paper reports results from the first measurements made on the exterior of a LEO spacecraft of mean dose equivalent rate and average quality factor as functions of shielding depth for shielding less than 1 g/cm2 Al equivalent. Two sets of measurements were made on the outside of the Mir Orbital Station; one near solar maximum in June 1991 and one near solar minimum in 1997. Absorbed dose was measured using stacks of TLDs. LET spectrum from charged particles of LET infinity H2O > o r= 5keV/micrometers was measured using stacks of CR-39 PNTDs. Results from the TLD and PNTD measurements at a given shielding depth were combined to yield mean total dose rate, mean dose equivalent rate, and average quality factor. Measurements made near solar maximum tend to be greater than those made during solar minimum. Both mean dose rate and mean dose equivalent rate decrease by nearly four orders of magnitude within the first g/cm2 shielding illustrating the attenuation of both trapped electrons and low-energy trapped protons. In order to overcome problems with detector saturation after standard chemical processing, measurement of LET spectrum in the least shielded CR-39 PNTD layer (0.005 g/cm2 Al) was carried out using an atomic force microscope.


International Journal of Radiation Applications and Instrumentation. Part D. Nuclear Tracks and Radiation Measurements | 1986

Response of different types of CR-39 to energetic ions

E.V. Benton; K. Ogura; A.L. Frank; T.M. Atallah; V. Rowe

It is well known that the addition of small amounts of certain chemical additives to CR-39 will effect changes in its sensitivity, response and surface characteristics. We have studied the effect of adding small amounts of antioxidants to the monomer before casting. Stacks consisting of three types of CR-39 plastic were exposed to different energetic ions from proton through 56Fe in order to study the track response properties. Response of each CR-39 type was investigated, covering a wide LET, Z and β region. We have also shown that the most sensitive of these materials registers tracks of relativistic boron ions and 16 MeV protons at normal incidence.


International Journal of Radiation Applications and Instrumentation. Part D. Nuclear Tracks and Radiation Measurements | 1990

Differential neutron energy spectra measured on spacecraft in low earth orbit

V.E. Dudkin; Yu.V. Potapov; A.B. Akopova; L.V. Melkumyan; E.V. Benton; A.L. Frank

Two methods for measuring neutrons in the range from thermal energies to dozens of MeV were used. In the first method, alpha-particles emitted from the 6Li(n,alpha)T reaction are detected with the help of plastic nuclear track detectors, yielding results on thermal and resonance neutrons. Also, fission foils are used to detect fast neutrons. In the second method, fast neutrons are recorded by nuclear photographic emulsions (NPE). The results of measurements on board various satellites are presented. The neutron flux density does not appear to correlate clearly with orbital parameters. Up to 50% of neutrons are due to albedo neutrons from the atmosphere while the fluxes inside the satellites are 15-20% higher than those on the outside. Estimates show that the neutron contribution to the total equivalent radiation dose reaches 20-30%.


Radiation Measurements | 1996

Intercomparison of radiation measurements on STS-63

G.D. Badhwar; William Atwell; B. Cash; M. Weyland; Vladislav M. Petrov; I.V. Tchernykh; Yu.A. Akatov; V.A. Shurshakov; V.V. Arkhangelsky; V.V. Kushin; N.A. Klyachin; E.V. Benton; A.L. Frank; E. R. Benton; L.A. Frigo; V.E. Dudkin; Yu.V. Potapov; N. Vana; W. Schoner; M. Fugger

A joint NASA Russia study of the radiation environment inside the Space Shuttle was performed on STS-63. This was the second flight under the Shuttle-Mir Science Program (Phase 1). The Shuttle was launched on 2 February 1995, in a 51.65 degrees inclination orbit and landed at Kennedy Space Center on 11 February 1995, for a total flight duration of 8.27 days. The Shuttle carried a complement of both passive and active detectors distributed throughout the Shuttle volume. The crew exposure varied from 1962 to 2790 microGy with an average of 2265.8 microGy or 273.98 microGy/day. Crew exposures varied by a factor of 1.4, which is higher than usual for STS mission. The flight altitude varied from 314 to 395 km and provided a unique opportunity to obtain dose variation with altitude. Measurements of the average east-west dose variation were made using two active solid state detectors. The dose rate in the Spacehab locker, measured using a tissue equivalent proportional counter (TEPC), was 413.3 microGy/day, consistent with measurements made using thermoluminescent detectors (TLDs) in the same locker. The average quality factor was 2.33, and although it was higher than model calculations, it was consistent with values derived from high temperature peaks in TLDs. The dose rate due to galactic cosmic radiation was 110.6 microGy/day and agreed with model calculations. The dose rate from trapped particles was 302.7 microGy/day, nearly a factor of 2 lower than the prediction of the AP8 model. The neutrons in the intermediate energy range of 1-20 MeV contributed 13 microGy/day and 156 microSv/day, respectively. Analysis of data from the charged particle spectrometer has not yet been completed.


International Journal of Radiation Applications and Instrumentation. Part D. Nuclear Tracks and Radiation Measurements | 1992

Neutron fluences and energy spectra in the Cosmos-2044 biosatellite orbit

V.E. Dudkin; Yu.V. Potapov; A.B. Akopova; L.V. Melkumyan; Sh.B. Rshtuni; E.V. Benton; A.L. Frank

Joint Soviet-American measurements of the neutron component of space radiation (SR) were carried out during the flight of the Soviet biosatellite Cosmos-2044. Neutron flux densities and differential energy spectra were measured inside and on the external surface of the spacecraft. Three energy intervals were employed: thermal (En < or = 0.2 eV), resonance (0.2 eV < En < 1.0 MeV) and fast (En > or = 1.0 MeV) neutrons. The first two groups were measured with U.S. 6LiF detectors, while fast neutrons were recorded both by U.S. fission foils and Soviet nuclear emulsions. Estimations were made of the contributions to absorbed and equivalent doses from each neutron energy interval and a correlation was presented between fast neutron fluxes, measured outside the satellite, and the phase of solar activity (SA). Average dose equivalent rates of 0.018 and 0.14 mrem d-1 were measured for thermal and resonance neutrons, respectively, outside the spacecraft. The corresponding values for fast neutrons were 3.3 (U.S.) and 1.8 (U.S.S.R.) mrem d-1. Inside the spacecraft, a value of 3.5 mrem d-1 was found.


Radiation Measurements | 1994

HZE beam transport in multilayered materials

Judy L. Shinn; John Wilson; F. F. Badavi; E.V. Benton; I. Csige; A.L. Frank; E. R. Benton

A nonperturbative analytic solution of the high charge and energy (HZE) Greens function is used to implement a computer code for laboratory ion beam transport in multiple-layered materials. The code is established to operate on the Langley nuclear fragmentation model used in space engineering applications. Computational procedures are established to generate linear energy transfer (LET) distributions for a specified ion beam and target for comparison with experimental measurement. Comparison with 56Fe ion with Pb-Al and Pb-(CH2)x targets shows reasonable agreement.


International Journal of Radiation Applications and Instrumentation. Part D. Nuclear Tracks and Radiation Measurements | 1992

Ionizing radiation exposure of LDEF (pre-recovery estimates)

E.V. Benton; W. Heinrich; T. A. Parnell; T.W. Armstrong; James H. Derrickson; G. J. Fishman; A.L. Frank; J. W. Watts; B. Wiegel

The long duration exposure facility (LDEF), launched into a 258 nautical mile orbit with an inclination of 28.5 degrees, remained in space for nearly 6 yr. The 21,500 lb NASA satellite was one of the largest payloads ever deployed by the Space Shuttle. LDEF completed 32,422 orbits and carried 57 major experiments representing more than 200 investigators from 33 private companies, 21 universities and nine countries. The experiments covered a wide range of disciplines including basic science, electronics, optics, materials, structures and power and propulsion. A number of the experiments were specifically designed to measure the radiation environment. These experiments are of specific interest, since the LDEF orbit is essentially the same as that of the Space Station Freedom. Consequently, the radiation measurements on LDEF will play a significant role in the design of radiation shielding of the space station. The contributions of the various authors presented here attempt to predict the major aspects of the radiation exposure received by the various LDEF experiments and therefore should be helpful to investigators who are in the process of analyzing experiments which may have been affected by exposure to ionizing radiation. The paper discusses the various types and sources of ionizing radiation including cosmic rays, trapped particles (both protons and electrons) and secondary particles (including neutrons, spallation products and high-LET recoils), as well as doses and LET spectra as a function of shielding. Projections of the induced radioactivity of LDEF are also discussed.


Radiation Measurements | 2000

TLD efficiency of 7LiF for doses deposited by high-LET particles

E.R. Benton; A.L. Frank; E.V. Benton

The efficiency of 7 LiF TLDs (TLD-700) in registering dose from high-LET (> or = 10 keV/micrometers) charged particles (relative to 137Cs gamma rays) has been measured for a number of accelerated heavy ions at various particle accelerator facilities. These measured efficiency values have been compared with similar results obtained from the open literature and a dose efficiency function has been fitted to the combined data set. While it was found that the dose efficiency is not only a function of LET, but also of the charge of the incident particle, the fitted function can be used to correct the undermeasured value of dose from exposures made in mixed radiation fields where LET information is available. This LET-dependent dose efficiency function is used in our laboratory in determining total absorbed dose and dose equivalent from combined TLD and CR-39 plastic nuclear track detector measurements.


Radiation Measurements | 2001

Neutron dosimetry in low-earth orbit using passive detectors

E.R. Benton; E.V. Benton; A.L. Frank

This paper summarizes neutron dosimetry measurements made by the USF Physics Research Laboratory aboard US and Russian LEO spacecraft over the past 20 years using two types of passive detector. Thermal/resonance neutron detectors exploiting the 6Li(n,T) alpha reaction were used to measure neutrons of energies <1 MeV. Fission foil neutron detectors were used to measure neutrons of energies above 1 MeV. While originally analysed in terms of dose equivalent using the NCRP-38 definition of quality factor, for the purposes of this paper the measured neutron data have been reanalyzed and are presented in terms of ambient dose equivalent. Dose equivalent rate for neutrons <1 MeV ranged from 0.80 microSv/d on the low altitude, low inclination STS-41B mission to 22.0 microSv/d measured in the Shuttles cargo bay on the highly inclined STS-51F Spacelab-2 mission. In one particular instance a detector embedded within a large hydrogenous mass on STS-61 (in the ECT experiment) measured 34.6 microSv/d. Dose equivalent rate measurements of neutrons >1 MeV ranged from 4.5 microSv/d on the low altitude STS-3 mission to 172 microSv/d on the ~6 year LDEF mission. Thermal neutrons (<0.3 eV) were observed to make a negligible contribution to neutron dose equivalent in all cases. The major fraction of neutron dose equivalent was found to be from neutrons >1 MeV and, on LDEF, neutrons >1 MeV are responsible for over 98% of the total neutron dose equivalent. Estimates of the neutron contribution to the total dose equivalent are somewhat lower than model estimates, ranging from 5.7% at a location under low shielding on LDEF to 18.4% on the highly inclined (82.3 degrees) Biocosmos-2044 mission.

Collaboration


Dive into the A.L. Frank's collaboration.

Top Co-Authors

Avatar

E.V. Benton

University of San Francisco

View shared research outputs
Top Co-Authors

Avatar

V.E. Dudkin

Yerevan Physics Institute

View shared research outputs
Top Co-Authors

Avatar

E.R. Benton

University of San Francisco

View shared research outputs
Top Co-Authors

Avatar

L.A. Frigo

University of San Francisco

View shared research outputs
Top Co-Authors

Avatar

A.B. Akopova

Yerevan Physics Institute

View shared research outputs
Top Co-Authors

Avatar

Yu.V. Potapov

Yerevan Physics Institute

View shared research outputs
Top Co-Authors

Avatar

E. R. Benton

University of San Francisco

View shared research outputs
Top Co-Authors

Avatar

I. Csige

University of San Francisco

View shared research outputs
Top Co-Authors

Avatar

L.V. Melkumyan

Yerevan Physics Institute

View shared research outputs
Top Co-Authors

Avatar

N.V. Magradze

Yerevan Physics Institute

View shared research outputs
Researchain Logo
Decentralizing Knowledge