A. N. Kvashnin
Budker Institute of Nuclear Physics
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by A. N. Kvashnin.
ieee-npss real-time conference | 2014
Svetlana V. Ivanenko; A. D. Khil'chenko; Ekaterina A. Puryga; P. V. Zubarev; A. N. Kvashnin; V. Ovchar; A. Ivanova; Aleksandr Kotelnikov
Thomson scattering diagnostic is the most reliable and widely used method to measure electron temperature and density profiles of magnetically confined plasma. The prototype of data acquisition system for ITER divertor zone Thomson scattering diagnostic has been recently developed at the Budker Institute of Nuclear Physics (Novosibirsk, Russia). The small power (~10-8W) and short duration (~3-5 ns) are the main technical problems of the diagnostic. For detection and recording such low level signals the prototype of uniquely designed complex data acquisition system was developed. This system consists of 48 photodetector modules with 0-200MHz bandwidth, 48 simultaneously sampling ADC modules and synchronization subsystem. The photodetector modules are based on avalanche photodiodes and extremely low noise transimpedance preamplifiers. ADC modules include fast analog to digital convertors and digital units based on the Field-Programmable Gate Array for data processing and storage. The synchronization subsystem is used to form triggering pulses and to organize the simultaneously mode of ADC modules operation. Features of the system allow detection and recording short duration (3-5 ns) scattered pulses with 2GHz sampling rate and 10-bit total resolution in oscilloscope mode. At present, the system is tested on GLOBUS tokamak (St. Petersburg, Russia).
Instruments and Experimental Techniques | 2004
A. V. Burdakov; A. N. Kvashnin; V. S. Koidan; V. V. Postupaev; A. F. Rovenskikh; A. D. Khil'chenko
Using the upgrading of the measuring system of the GOL-3 plasma facility as an example, the structure of hardware and software environment developed for data-acquisition systems of large pulse electrophysical plants is considered. The equipment is built into 3U-size 19-inch subracks. The control computers are connected to the measuring equipment via standard network facilities (Ethernet-10/100 interface and TCP/IP protocol). At present, we have begun making basic diagnostic measurements using the ADC1250/32 multichannel synchronous data-acquisition systems.
Instruments and Experimental Techniques | 2003
V. F. Gurko; P. V. Zubarev; A. N. Kvashnin; D. V. Moiseev; A. D. Khil'chenko; V. A. Khil'chenko
The system is intended for recording data in the multichannel diagnostic sections of experimental plasma facilities. It contains eight four-channel modules that record the shapes of single pulse signals, a controller module of the system bus of the crate, a fiber-optic communication line, and an interface card for connection to the ISA bus of a personal computer. The recording modules are based on 12-bit analog-to-digital converters (ADCs) with a sampling frequency of up to 50 MHz, ensuring a conversion accuracy equal to the least significant bit in a band of the input signal of up to 20 MHz. The ADC samples are fixed in 32-Kword/channel buffer storage units with a page organization. The current values of the amplitude of the input signals in all of the recording channels are measured simultaneously with a time jitter of no more than 0.2 ns. The software selects an amplitude conversion scale and a zero offset voltage value for each recording channel, as well as the current value of the sampling frequency for all the channels.
Review of Scientific Instruments | 2015
A. Lizunov; A. D. Khil'chenko; V. A. Khil'chenko; A. N. Kvashnin; P. V. Zubarev
A spectrometer based on a linear array photomultiplier tube (PMT) has been developed and calibrated. A 0.635 m focal length Czerny-Turner monochromator combined with a coupling optics provides an image of a narrow 0.5 nm spectral range with a resolution of 0.015 nm/channel on a 32-anode PMT. The system aims at spectroscopy of D(α) or H(α) lines emitted by a diagnostic atomic beam in a plasma (primarily a motional Stark effect diagnostics). To record a low photon flux of ∼10(6) s(-1) per channel with the time resolution of 100 μs, a pulse counting approach has been used. Wideband amplifiers scale single-electron pulses and transmit them to a digital data processing core hardwired in a programmable logic matrix. Calibrations have shown that the aberration-limited instrument function fits to a single detector channel of 1 mm width. Pilot results of passive measurements of D(α) light emission from the plasma confined in a magnetic trap are presented.
international conference on advancements in nuclear instrumentation measurement methods and their applications | 2015
Svetlana V. Ivanenko; A. D. Khil'chenko; V. Ovchar; P. V. Zubarev; A. N. Kvashnin; Ekaterina A. Puryga; A. Ivanova; L. B. Epshteyn; Aleksandr Kotelnikov
Uniquely designed complex data acquisition system for Thomson scattering diagnostic was developed. It allows recording short duration (3-5 ns) scattered pulses with 2GHz sampling rate and 10-bit total resolution. The system consists up to 48 photo detector modules with 0-200MHz bandwidth, 1-48 simultaneously sampling ADC modules and synchronization subsystem. The photo detector modules are based on avalanche photodiodes and ultra-low noise transimpedance amplifiers. ADC modules include fast analog to digital convertors and digital units based on the Field-Programmable Gate Array for data processing and storage. The synchronization subsystem is used to form triggering pulses and to organize the simultaneously mode of ADC modules operation.
Instruments and Experimental Techniques | 2003
V. F. Gurko; P. V. Zubarev; A. N. Kvashnin; D. V. Moiseev; A. D. Khil'chenko
The simultaneously sampling data acquisition system contains 16 eight-channel modules, which record the shapes of single pulse signals, and the controller module of the system bus of the Eurocrate, which interacts with the basic computer of the diagnostic complex via an Ethernet-FX communication line supported by TCP/IP protocols. The recording modules are based on 12-bit analog-to-digital converters (ADC). The ADC samples are fixed in buffer storage units with a capacity of up to 1 Mword/channel. The current amplitudes of the input signals are measured simultaneously in all recording channels with a time jitter of ∼3 ns. The maximum sampling frequency is below 4 MHz.
Instruments and Experimental Techniques | 2003
V. F. Gurko; P. V. Zubarev; A. N. Kvashnin; A. D. Khil'chenko
The backbone of the system is an eight-channel recording module based on a unique circuit of a precision phase detector with a resolution of <0.5 mrad at a 1-MHz carrier frequency and in a 0- to 500-kHz modulation band. The dynamic range of each channel of the recording module varies from –250 to +250 rad.
ieee-npss real-time conference | 2014
Alina A. Ivanova; Vladimir N. Amosov; Dmitry A. Skopintsev; Aleksandr D. Khilchenko; A. N. Kvashnin; P. V. Zubarev; Svetlana V. Ivanenko; Aleksandr Kotelnikov; Ekaterina A. Puryga
This paper proposes the approach to development of real time digital pulse analyzer of diamond detector for ITER Vertical Neutron Camera. It consists in the hardware implementation of data pre-processing unit. This approach reduces requirements of communication channels bandwidth and requirements of computing performance. Analyzer hardware platform is ADC12500PXIe recorder (2 channels, 12-bit, 500 MHz, PXI Express). The article describes the architecture of digital signal processing unit.
ieee-npss real-time conference | 2014
Aleksandr Kotelnikov; A. N. Kvashnin; Oleg Meshkov; A. D. Khil'chenko; Svetlana V. Ivanenko; Alina A. Ivanova; Ekaterina A. Puryga; P. V. Zubarev
The real-time processing of the electron beam parameters is a necessary procedure to optimize the key characteristics of the synchrotron radiation source. To study multi-bunch beam instabilities a high-speed electron beam profile monitor is developed. The device described must continuously implement 15625000 measurements of the vertical or horizontal electron beam profile at 16 points with a time resolution of 5 ns at 50 MHz rate.
Instruments and Experimental Techniques | 2001
P. V. Zubarev; A. N. Kvashnin; A. D. Khil'chenko; V. A. Khil'chenko
A data acquisition system containing up to four multichannel galvanically insulated modules capable of recording the shapes of single pulse signals is described. The recording modules are built on 12-bit ADC with sampling frequencies of 0.5 and 40 MHz and connected by serial fiber-optic communication lines to an interface board, which connects them to an ISA bus. The system is intended for the multichannel diagnostic sections of plasma setups.