A. Wilhelm Neumann
University of Toronto
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by A. Wilhelm Neumann.
Pediatric Research | 2006
Yi Y. Zuo; Hamdi Alolabi; Arash Shafiei; Ningxi Kang; Zdenka Policova; Peter N. Cox; Edgar J. Acosta; Michael L. Hair; A. Wilhelm Neumann
Chitosan is a natural, cationic polysaccharide derived from fully or partially deacetylated chitin. Chitosan is capable of inducing large phospholipid aggregates, closely resembling the function of nonionic polymers tested previously as additives to therapeutic lung surfactants. The effects of chitosan on improving the surface activity of a dilute lung surfactant preparation, bovine lipid extract surfactant (BLES), and on resisting albumin-induced inactivation were studied using a constrained sessile drop (CSD) method. Also studied in parallel were the effects of polyethylene glycol (PEG, 10 kD) and hyaluronan (HA, 1240 kD). Both adsorption and dynamic cycling studies showed that chitosan is able to significantly enhance the surface activity of 0.5 mg/mL BLES and to resist albumin-induced inactivation at an extremely low concentration of 0.05 mg/mL, 1000 times smaller than the usual concentration of PEG and 20 times smaller than HA. Optical microscopy found that chitosan induced large surfactant aggregates even in the presence of albumin. Cytotoxicity tests confirmed that chitosan has no deleterious effect on the viability of lung epithelial cells. The experimental results suggest that chitosan may be a more effective polymeric additive to lung surfactant than the other polymers tested so far.
Annals of Biomedical Engineering | 1983
Jacques Chappuis; Igor A. Sherman; A. Wilhelm Neumann
Measurements of the surface tension of articular cartilage and friction experiments were carried out to provide further evidence in support of a new theory regarding the mechanism of friction in joints. To determine the surface tension of cartilage, contact angle measurements were used in conjunction with the equation of state for interfacial tensions. The advancing contact angle between saline drops and articular cartilage was found to be 100°±5°, indicating a highly hydrophobic surface. The corresponding surface tension value was calculated to be 22.5 ergs/cm2. Friction of cartilage against hydrophobic surfaces is shown to be lower than the friction of cartilage against hydrophilic surfaces. All these results further support the theory that lubrication by nonwetting drops occurs in joints and may be responsible for the exceptional friction characteristics of the joints.
Biophysical Journal | 2009
Ali Kalantarian; Hiromasa Ninomiya; Sameh M.I. Saad; Robert David; Rudolf Winklbauer; A. Wilhelm Neumann
Biological tissues behave in certain respects like liquids. Consequently, the surface tension concept can be used to explain aspects of the in vitro and in vivo behavior of multicellular aggregates. Unfortunately, conventional methods of surface tension measurement cannot be readily applied to small cell aggregates. This difficulty can be overcome by an experimentally straightforward method consisting of centrifugation followed by axisymmetric drop shape analysis (ADSA). Since the aggregates typically show roughness, standard ADSA cannot be applied and we introduce a novel numerical method called ADSA-IP (ADSA for imperfect profile) for this purpose. To examine the new methodology, embryonic tissues from the gastrula of the frog, Xenopus laevis, deformed in the centrifuge are used. It is confirmed that surface tension measurements are independent of centrifugal force and aggregate size. Surface tension is measured for ectodermal cells in four sample batches, and varies between 1.1 and 7.7 mJ/m2. Surface tension is also measured for aggregates of cells expressing cytoplasmically truncated EP/C-cadherin, and is approximately half as large. In parallel, such aggregates show a reduction in convergent extension-driven elongation after activin treatment, reflecting diminished intercellular cohesion.
Current Opinion in Colloid and Interface Science | 1996
Robert M. Prokop; A. Wilhelm Neumann
The classical methods used to investigate the surface activity of lung surfactant are the Langmuir-Wilhelmy surface balance and the pulsating bubble surfactometer. Over the past few years, it has become increasingly apparent that these methods are inadequate in many respects. These shortcomings, however, have been overcome by recent developments in lung surfactant methodologies: the captive bubble surfactometer and axisymmetric drop shape analysis.
Advances in Colloid and Interface Science | 2014
Sameh M.I. Saad; A. Wilhelm Neumann
Drop shape techniques are used extensively for surface tension measurement. It is well-documented that, as the drop/bubble shape becomes close to spherical, the performance of all drop shape techniques deteriorates. There have been efforts quantifying the range of applicability of drop techniques by studying the deviation of Laplacian drops from the spherical shape. A shape parameter was introduced in the literature and was modified several times to accommodate different drop constellations. However, new problems arise every time a new configuration is considered. Therefore, there is a need for a universal shape parameter applicable to pendant drops, sessile drops, liquid bridges as well as captive bubbles. In this work, the use of the total Gaussian curvature in a unified approach for the shape parameter is introduced for that purpose. The total Gaussian curvature is a dimensionless quantity that is commonly used in differential geometry and surface thermodynamics, and can be easily calculated for different Laplacian drop shapes. The new definition of the shape parameter using the total Gaussian curvature is applied here to both pendant and constrained sessile drops as an illustration. The analysis showed that the new definition is superior and reflects experimental results better than previous definitions, especially at extreme values of the Bond number.
Colloids and Surfaces B: Biointerfaces | 1997
Ajay Jyoti; Robert M. Prokop; A. Wilhelm Neumann
Using axisymmetric drop shape analysis as a film balance, the surface properties of a dipalmitoylphosphatidylcholine monolayer at the air-water interface were investigated. In particular, the controversial liquid-expanded/liquid-condensed (LE/LC) phase transition of the surface pressure-surface area isotherm was examined. The results indicate that the manifestation of this transition is dependent on the method used to form the monolayer. A ‘surface deposition’ method results in a high concentration of lipid at the interface, and compression of this type of monolayer produces the LE/LC transition. When the monolayer is formed using ‘bulk deposition,’ this transition does not occur. The proposed process of lipid arrangement for this type of monolayer is gaseous phase (G), G (or LE)-LC-solid phase (SC), and SC. Hence the LC phase is present throughout the middle region of the isotherm.
Langmuir | 2009
Sameh M.I. Saad; Zdenka Policova; Edgar J. Acosta; Michael L. Hair; A. Wilhelm Neumann
A drop shape technique using a constrained sessile drop constellation (ADSA-CSD) has been introduced as a superior technique for studying spread films specially at high collapse pressures [Saad et al. Langmuir 2008, 24, 10843-10850]. It has been shown that ADSA-CSD has certain advantages including the need only for small quantities of liquid and insoluble surfactants, the ability to measure very low surface tension values, easier deposition procedure, and leak-proof design. Here, this technique was applied to investigate mixed DPPC/DPPG monolayers to characterize the role of such molecules in maintaining stable film properties and surface activity of lung surfactant preparations. Results of compression isotherms were obtained for different DPPC/DPPG mixture ratios: 90/10, 80/20, 70/30, 60/40, and 50/50 in addition to pure DPPC and pure DPPG at room temperature of 24 degrees C. The ultimate collapse pressure of DPPC/DPPG mixtures was found to be 70.5 mJ/m2 (similar to pure DPPC) for the cases of low DPPG content (up to 20%). Increasing the DPPG content in the mixture (up to 40%) caused a slight decrease in the ultimate collapse pressure. However, further increase of DPPG in the mixture (50% or more) caused a sharp decrease in the ultimate collapse pressure to a value of 59.9 mJ/m2 (similar to pure DPPG). The change in film elasticity was also tracked for the range of mixture ratios studied. The physical reasons for such changes and the interaction between DPPC and DPPG molecules are discussed. The results also show a change in the film hysteresis upon successive compression and expansion cycles for different mixture ratios.
Langmuir | 2008
Sameh M.I. Saad; Zdenka Policova; Edgar J. Acosta; A. Wilhelm Neumann
Collapse pressure of insoluble monolayers is a property determined from surface pressure/area isotherms. Such isotherms are commonly measured by a Langmuir film balance or a drop shape technique using a pendant drop constellation (ADSA-PD). Here, a different embodiment of a drop shape analysis, called axisymmetric drop shape analysis-constrained sessile drop (ADSA-CSD) is used as a film balance. It is shown that ADSA-CSD has certain advantages over conventional methods. The ability to measure very low surface tension values (e.g., <2 mJ/m2), an easier deposition procedure than in a pendant drop setup, and leak-proof design make the constrained sessile drop constellation a better choice than the pendant drop constellation in many situations. Results of compression isotherms are obtained on three different monolayers: octadecanol, dipalmitoyl-phosphatidyl-choline (DPPC), and dipalmitoyl-phosphatidyl-glycerol (DPPG). The collapse pressures are found to be reproducible and in agreement with previous methods. For example, the collapse pressure of DPPC is found to be 70.2 mJ/m2. Such values are not achievable with a pendant drop. The collapse pressure of octadecanol is found to be 61.3 mJ/m2, while that of DPPG is 59.0 mJ/m2. The physical reasons for these differences are discussed. The results also show a distinctive difference between the onset of collapse and the ultimate collapse pressure (ultimate strength) of these films. ADSA-CSD allows detailed study of this collapse region.
Colloids and Surfaces B: Biointerfaces | 2009
Sameh M.I. Saad; Zdenka Policova; Andrew Dang; Edgar J. Acosta; Michael L. Hair; A. Wilhelm Neumann
This paper presents a continuation of the development of a drop shape method for film studies, ADSA-CSD (Axisymmetric Drop Shape Analysis-Constrained Sessile Drop). ADSA-CSD has certain advantages over conventional methods. The development presented here allows complete exchange of the subphase of a spread or adsorbed film. This feature allows certain studies relevant to lung surfactant research that cannot be readily performed by other means. The key feature of the design is a second capillary into the bulk of the drop to facilitate addition or removal of a secondary liquid. The development will be illustrated through studies concerning lung surfactant inhibition. After forming a sessile drop of a basic lung surfactant preparation, the bulk phase can be removed and exchanged for one containing different inhibitors. Such studies mimic the leakage of plasma and blood proteins into the alveolar spaces altering the surface activity of lung surfactant in a phenomenon called surfactant inhibition. The resistance of the lung surfactant to specific inhibitors can be readily evaluated using the method. The new method is also useful for surfactant reversal studies, i.e. the ability to restore the normal surface activity of an inhibited lung surfactant film by using special additives. Results show a distinctive difference between the inhibition when an inhibitor is mixed with and when it is injected under a preformed surfactant film. None of the inhibitors studied (serum, albumin, fibrinogen, and cholesterol) were able to penetrate a preexisting film formed by the basic preparation (BLES and protasan), while all of them can alter the surface activity of such preparation when mixed with the preparation. Preliminary results show that reversal of serum inhibition can be easily achieved and evaluated using the modified methodology.
Advances in Colloid and Interface Science | 2013
Ali Kalantarian; Sameh M.I. Saad; A. Wilhelm Neumann
Axisymmetric Drop Shape Analysis (ADSA) has been extensively used for surface tension measurement. In essence, ADSA works by matching a theoretical profile of the drop to the extracted experimental profile, taking surface tension as an adjustable parameter. Of the three main building blocks of ADSA, i.e. edge detection, the numerical integration of the Laplace equation for generating theoretical curves and the optimization procedure, only edge detection (that extracts the drop profile line from the drop image) needs extensive study. For the purpose of this article, the numerical integration of the Laplace equation for generating theoretical curves and the optimization procedure will only require a minor effort. It is the aim of this paper to investigate how far the surface tension accuracy of drop shape techniques can be pushed by fine tuning and optimizing edge detection strategies for a given drop image. Two different aspects of edge detection are pursued here: sub-pixel resolution and pixel resolution. The effect of two sub-pixel resolution strategies, i.e. spline and sigmoid, on the accuracy of surface tension measurement is investigated. It is found that the number of pixel points in the fitting procedure of the sub-pixel resolution techniques is crucial, and its value should be determined based on the contrast of the image, i.e. the gray level difference between the drop and the background. On the pixel resolution side, two suitable and reliable edge detectors, i.e. Canny and SUSAN, are explored, and the effect of user-specified parameters of the edge detector on the accuracy of surface tension measurement is scrutinized. Based on the contrast of the image, an optimum value of the user-specified parameter of the edge detector, SUSAN, is suggested. Overall, an accuracy of 0.01mJ/m(2) is achievable for the surface tension determination by careful fine tuning of edge detection algorithms.