Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Aaron R. Wheeler is active.

Publication


Featured researches published by Aaron R. Wheeler.


Critical Reviews in Biotechnology | 2006

Bio-Microarray Fabrication Techniques—A Review

Irena Barbulovic-Nad; Michael Lucente; Yu Sun; Mingjun Zhang; Aaron R. Wheeler; Markus Bussmann

ABSTRACT Microarrays with biomolecules (e.g., DNA and proteins), cells, and tissues immobilized on solid substrates are important tools for biological research, including genomics, proteomics, and cell analysis. In this paper, the current state of microarray fabrication is reviewed. According to spot formation techniques, methods are categorized as “contact printing” and “non-contact printing.” Contact printing is a widely used technology, comprising methods such as contact pin printing and microstamping. These methods have many advantages, including reproducibility of printed spots and facile maintenance, as well as drawbacks, including low-throughput fabrication of arrays. Non-contact printing techniques are newer and more varied, comprising photochemistry-based methods, laser writing, electrospray deposition, and inkjet technologies. These technologies emerged from other applications and have the potential to increase microarray fabrication throughput; however, there are several challenges in applying them to microarray fabrication, including interference from satellite drops and biomolecule denaturization.


Analytical and Bioanalytical Chemistry | 2010

Immunoassays in microfluidic systems

Alphonsus H. C. Ng; Uvaraj Uddayasankar; Aaron R. Wheeler

Immunoassays have greatly benefited from miniaturization in microfluidic systems. This review, which summarizes developments in microfluidics-based immunoassays since 2000, includes four sections, focusing on the configurations of immunoassays that have been implemented in microfluidics, the main fluid handling modalities that have been used for microfluidic immunoassays, multiplexed immunoassays in microfluidic platforms, and the emergence of label-free detection techniques. The field of microfluidic immunoassays is continuously improving and has great promise for the future.


Science | 2008

Putting Electrowetting to Work

Aaron R. Wheeler

Voltage pulses that cause changes in fluid shape or movement can be used to drive optical components and miniaturized assays.


Langmuir | 2008

Pluronic Additives: A Solution to Sticky Problems in Digital Microfluidics

Vivienne N. Luk; Gary Ch. Mo; Aaron R. Wheeler

Digital microfluidics (DMF) is a promising technique for carrying out miniaturized, automated biochemical assays in which discrete droplets of reagents are actuated on the surface of an array of electrodes. A limitation for DMF is nonspecific protein adsorption to device surfaces, which interferes with assay fidelity and can cause droplets to become unmovable. Here, we report the results of a quantitative analysis of protein adsorption on DMF devices by means of confocal microscopy and secondary ion mass spectrometry. This study led us to a simple and effective method for limiting the extent of protein adsorption: the use of low concentrations of Pluronic F127 as a solution additive. This strategy has a transformative effect on digital microfluidics, facilitating the actuation of droplets containing greater than 1000-fold higher protein concentrations than is possible without the additive. To illustrate the benefits of this new method, we implemented a DMF-driven protein digest assay using large concentrations (1 mg/mL) of protein-substrate. The use of Pluronic additives solves a sticky problem in DMF, which greatly expands the range of applications that are compatible with this promising technology.


Analytical Chemistry | 2008

A Digital Microfluidic Approach to Homogeneous Enzyme Assays

Elizabeth M. Miller; Aaron R. Wheeler

A digital microfluidic device was applied to a variety of enzymatic analyses. The digital approach to microfluidics manipulates samples and reagents in the form of discrete droplets, as opposed to the streams of fluid used in channel microfluidics. This approach is more easily reconfigured than a channel device, and the flexibility of these devices makes them suitable for a wide variety of applications. Alkaline phosphatase was chosen as a model enzyme and used to convert fluorescein diphosphate into fluorescein. Droplets of alkaline phosphatase and fluorescein diphosphate were merged and mixed on the device, resulting in a 140-nL, stopped-flow reaction chamber in which the fluorescent product was detected by a fluorescence plate reader. Substrate quantitation was achieved with a linear range of 2 orders of magnitude and a detection limit of approximately 7.0 x 10-20 mol. Addition of a small amount of a nonionic surfactant to the reaction buffer was shown to reduce the adsorption of enzyme to the device surface and extend the lifetime of the device without affecting the enzyme activity. Analyses of the enzyme kinetics and the effects of inhibition with inorganic phosphate were performed, and Km and kcat values of 1.35 microM and 120 s-1, respectively, agreed with those obtained in a conventional 384-well plate under the same conditions (1.85 microM and 155 s-1). A phototype device was also developed to perform multiplexed enzyme analyses. It was concluded that the digital microfluidic format is able to perform detailed and reproducible assays of substrate concentrations and enzyme activity in much smaller reaction volumes and with higher sensitivity than conventional methods.


Analytical Chemistry | 2012

Digital Microfluidic Magnetic Separation for Particle-Based Immunoassays

Alphonsus H. C. Ng; Kihwan Choi; Robert P. Luoma; John M. Robinson; Aaron R. Wheeler

We introduce a new format for particle-based immunoassays relying on digital microfluidics (DMF) and magnetic forces to separate and resuspend antibody-coated paramagnetic particles. In DMF, fluids are electrostatically controlled as discrete droplets (picoliters to microliters) on an array of insulated electrodes. By applying appropriate sequences of potentials to these electrodes, multiple droplets can be manipulated simultaneously and various droplet operations can be achieved using the same device design. This flexibility makes DMF well-suited for applications that require complex, multistep protocols such as immunoassays. Here, we report the first particle-based immunoassay on DMF without the aid of oil carrier fluid to enable droplet movement (i.e., droplets are surrounded by air instead of oil). This new format allowed the realization of a novel on-chip particle separation and resuspension method capable of removing greater than 90% of unbound reagents in one step. Using this technique, we developed methods for noncompetitive and competitive immunoassays, using thyroid stimulating hormone (TSH) and 17β-estradiol (E2) as model analytes, respectively. We show that, compared to conventional methods, the new DMF approach reported here reduced reagent volumes and analysis time by 100-fold and 10-fold, respectively, while retaining a level of analytical performance required for clinical screening. Thus, we propose that the new technique has great potential for eventual use in a fast, low-waste, and inexpensive instrument for the quantitative analysis of proteins and small molecules in low sample volumes.


Nature Materials | 2016

Biodegradable scaffold with built-in vasculature for organ-on-a-chip engineering and direct surgical anastomosis

Boyang Zhang; Miles Montgomery; M. Dean Chamberlain; Shinichiro Ogawa; Anastasia Korolj; Aric Pahnke; Laura A. Wells; Stephane Masse; Jihye Kim; Lewis A. Reis; Sara S. Nunes; Aaron R. Wheeler; Kumaraswamy Nanthakumar; Gordon Keller; Michael V. Sefton; Milica Radisic

We report the fabrication of a scaffold (hereafter referred to as AngioChip) that supports the assembly of parenchymal cells on a mechanically tunable matrix surrounding a perfusable, branched, three-dimensional microchannel network coated with endothelial cells. The design of AngioChip decouples the material choices for the engineered vessel network and for cell seeding in the parenchyma, enabling extensive remodelling while maintaining an open-vessel lumen. The incorporation of nanopores and micro-holes in the vessel walls enhances permeability, and permits intercellular crosstalk and extravasation of monocytes and endothelial cells on biomolecular stimulation. We also show that vascularized hepatic tissues and cardiac tissues engineered by using AngioChips process clinically relevant drugs delivered through the vasculature, and that millimeter-thick cardiac tissues can be engineered in a scalable manner. Moreover, we demonstrate that AngioChip cardiac tissues implanted via direct surgical anastomosis to the femoral vessels of rat hindlimbs establish immediate blood perfusion.


Biomaterials | 2010

A circular cross-section PDMS microfluidics system for replication of cardiovascular flow conditions

Lindsey K. Fiddes; Neta Raz; Suthan Srigunapalan; Ethan Tumarkan; Craig A. Simmons; Aaron R. Wheeler; Eugenia Kumacheva

Since the inception of soft lithography, microfluidic devices for cardiovascular research have been fabricated easily and cost-effectively using the soft lithography method. The drawback of this method was the fabrication of microchannels with rectangular cross-sections, which did not replicate the circular cross-sections of blood vessels. This article presents a novel, straightforward approach for the fabrication of microchannels with circular cross-sections in poly(dimethylsiloxane) (PDMS), using soft lithography. The method exploits the polymerization of the liquid silicone oligomer around a gas stream when both of them are coaxially introduced in the microchannel with a rectangular cross-section. We demonstrate (i) the ability to control the diameter of circular cross-sections of microchannels from ca. 40-100 mum; (ii) the fabrication of microchannels with constrictions, and (iii) the capability to grow endothelial cells on the inner surface of the microchannels.


Lab on a Chip | 2007

Matrix-dependent adhesion of vascular and valvular endothelial cells in microfluidic channels{{

Edmond W. K. Young; Aaron R. Wheeler; Craig A. Simmons

The interactions between endothelial cells and the underlying extracellular matrix regulate adhesion and cellular responses to microenvironmental stimuli, including flow-induced shear stress. In this study, we investigated the adhesion properties of primary porcine aortic endothelial cells (PAECs) and valve endothelial cells (PAVECs) in a microfluidic network. Taking advantage of the parallel arrangement of the microchannels, we compared adhesion of PAECs and PAVECs to fibronectin and type I collagen, two prominent extracellular matrix proteins, over a broad range of concentrations. Cell spreading was measured morphologically, based on cytoplasmic staining with a vital dye, while adhesion strength was characterized by the number of cells attached after application of shear stresses of 11, 110, and 220 dyn cm(-2). Results showed that PAVECs were more well spread on fibronectin than on type I collagen (P < 0.0001), particularly for coating concentrations of 100, 200, and 500 microg mL(-1). PAVECs also withstood shear significantly better on fibronectin than on collagen for 500 microg mL(-1). PAECs were more well spread on collagen compared to PAVECs (P < 0.0001), but did not have significantly better adhesion strength. These results demonstrate that cell adhesion is both cell-type and matrix dependent. Furthermore, they reveal important phenotypic differences between vascular and valvular endothelium, with implications for endothelial mechanobiology and the design of microdevices and engineered tissues.


Lab on a Chip | 2007

Maze exploration and learning in C. elegans.

Jianhua Qin; Aaron R. Wheeler

The soil dwelling nematode, Caenorhabditis (C.) elegans, is a popular model system for studying behavioral plasticity. Noticeably absent from the C. elegans literature, however, are studies evaluating worm behavior in mazes. Here, we report the use of microfluidic mazes to investigate exploration and learning behaviors in wild-type C. elegans, as well as in the dopamine-poor mutant, cat-2. The key research findings include: (1)C. elegans worms are motivated to explore complex spatial environments with or without the presence of food/reward, (2) wild-type worms exhibit a greater tendency to explore relative to mutant worms, (3) both wild-type and mutant worms can learn to make unconditioned responses to food/reward, and (4) wild-type worms are significantly more likely to learn to make conditioned responses linking reward to location than mutant worms. These results introduce microfluidic mazes as a valuable new tool for biological behavioral analysis.

Collaboration


Dive into the Aaron R. Wheeler's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Hao Yang

University of Toronto

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge